论文部分内容阅读
蒙达1号炉自1995年投产以来,多次出现结焦及积灰问题。内蒙古电科院与蒙达公司技术人员在分析燃料及燃烧特性、锅炉设计因素、运行因素、设备存在的问题等方面的基础上,进行了燃烧优化及设备治理工作,将1号炉膛出口烟温降低了50℃以上,锅炉效率提高了0.552%,保证了烟气通
Munda 1 furnace since its commissioning in 1995, many coking and fouling problems. Based on the analysis of fuel and combustion characteristics, boiler design factors, operation factors and equipment problems, Inner Mongolia Electric Power Research Institute and Mengda Company’s technicians carried out combustion optimization and equipment control work. The output of No. 1 furnace flue gas temperature Reduced above 50 ℃, boiler efficiency increased by 0.552%, to ensure the flue gas pass