一、粮堆通风技术参数的计算(一)单位耗气量为了使粮堆完全冷却,需要通入一定量的冷空气。通常以每一立方米的粮食需要1000米~3的空气作为单位耗气量。单位耗气量=1000米~3空气/米~3粮食(注:在粮食冷却过程中,冷却空气带出的热量等于粮食散发出来的热量。冷却粮食所需的重量风量应是粮食比热与冷却空气的比值。若含水量为12%的粮食比热为0.44千卡/公斤0℃,空气的比热为0.24千卡/公斤0℃,则冷却粮食需要的风量比为1:1.8,即冷却一吨(约1.3—1.7立方米)粮食需要1800公斤的冷却空气。由于通风冷却时,粮食水份的蒸发会消耗一部份粮食的热量,实际需要的风量比为1:1。可以认为冷却一立方米的粮食需要1000米~3的风量。
First, the calculation of grain plenum ventilation technical parameters (A) unit air consumption In order to complete the cooling of the piles, the need to access a certain amount of cold air. Usually cubic meters per cubic meter of food needs 1000 meters to 3 units of air consumption as a unit. Unit Air Consumption = 1000m ~ 3 Air / m ~ 3 Grain (Note: During the cooling process, the amount of heat released by the cooling air is equal to the amount of heat dissipated by the food.) The amount of air required for cooling the food should be the specific heat and cooling Air ratio.If the water content of 12% of the food specific heat is 0.44 kcal / kg 0 ℃, the specific heat of air is 0.24 kcal / kg 0 ℃, the cooling air required for the air ratio of 1: 1.8, that is, cooling A ton of (about 1.3-1.7 cubic meters) grain requires 1800 kilograms of cooling air.When ventilation is cooling, the evaporation of food moisture consumes a portion of the food’s heat, and the actual required air volume ratio is 1: 1. Cooling can be considered One cubic meter of food needs 1000 meters ~ 3 air volume.