(1) Introduction In infrared thermal imaging instruments, optical mechanical scanning system is often used to make the detector according to a certain rule, sequentially receive the infrared radiation emitted by each object point of the observed space, the detector converts the received infrared radiation into Electrical signals, amplified by the electronic circuit, and then through the display device to give people a reflection of the scene temperature level and the original similar to the visible image. The scanning rules given by a practical scanning system must be linear or nearly linear. Non-linear scan will make the image distorted, and even give a wrong judgment, but the linear scan law is not always achievable, there is a conditional. Used as a scanning system optical components, in addition to the completion of the scanning task, will produce a certain amount of aberration. Sometimes sweep