论文部分内容阅读
基于二安替比林邻异丙氧基苯基甲烷(DA0IM)能被铬(Ⅵ)氧化显深色建立了一种测定生物样品中铬的新方法,方法灵敏度高,稳定性好,用于几种生物样品中铬的测定,结果满意。实验部分1 仪器和试剂722型分光光度计,1cm比色皿;铬(Ⅵ)标准液:10μg/ml?
A novel method for the determination of chromium in biological samples based on the oxidation of chromogenic (Ⅵ) chromium (Ⅵ) with diamyipinin o-isopropoxyphenylmethane (DAOIM) was developed. The method has high sensitivity and good stability and is suitable for Determination of chromium in several biological samples with satisfactory results. Experimental part 1 instruments and reagents 722 spectrophotometer, 1cm cuvette; chromium (Ⅵ) standard solution: 1 0μg / ml?