Ion-exclusion/anion-exchange chromatography(IEC/AEC) on a combination of a strongly basic anion-exchange resin in the OH——form with basic eluent has been developed.The separation mechanism is based on the ion-exclusion/penetration effect for cations and the anion-exchange effect for anions to anion-exchange resin phase.This system is useful for simultaneous separation and determination of ammonium ion(NH+4),nitrite ion(NO-2),and nitrate ion(NO-3) in water samples.The resolution of analyte ions can be manipulated by changing the concentration of base in eluent on a polystyrene-divinylbenzene based strongly basic anion-exchange resin column.In this study,several separation columns,which consisted of different particle sizes,different functional groups and different anion-exchange capacities,were compared.As the results,the separation column with the smaller anion-exchange capacity(TSKgel Super IC-Anion) showed well-resolved separation of cations and anions.In the optimization of the basic eluent,lithium hydroxide(LiOH) was used as the eluent and the optimal concentration was concluded to be 2 mmol/L,considering the resolution of analyte ions and the whole retention times.In the optimal conditions,the relative standard deviations of the peak areas and the retention times of NH+4,NO-2,and NO-3 ranged 1.28%-3.57% and 0.54%-1.55%,respectively.The limits of detection at signal-to-noise of 3 were 4.10 μmol/L for NH+4,1.87 μmol/L for NO-2 and 2.83 μmol/L for NO-3.
Ion-exclusion / anion-exchange chromatography (IEC / AEC) on a combination of a strongly basic anion-exchange resin in the OH - form with basic eluent has been developed. The separation mechanism is based on the ion-exclusion / penetration effect for cations and the anion-exchange effect for anions to anion-exchange resin phase. This system is useful for simultaneous separation and determination of ammonium ion (NH + 4), nitrite ion (NO-2), and nitrate ion ) in water samples. The resolution of analyte ions can be manipulated by changing the concentration of base in eluent on a polystyrene-divinylbenzene based strongly basic anion-exchange resin column. In this study, several separation columns, which consisted of different particle sizes, different functional groups and different anion-exchange capacities, were compared. As the results, the separation column with the smaller anion-exchange capacity (TSKgel Super IC-Anion) showed well-resolved separation of cations and anions. the optimization of the basic eluent, lithium hydroxide (LiOH) was used as the eluent and the optimal concentration was concluded to be 2 mmol / L, considering the resolution of analytes and the whole retention times. In the optimal conditions, the relative standard deviations of the peak areas and the retention times of NH + 4, NO-2, and NO-3 ranged 1.28% -3.57% and 0.54% -1.55%, respectively. These limits of detection at signal-to-noise of 3 were 4.10 μmol / L for NH + 4, 1.87 μmol / L for NO-2 and 2.83 μmol / L for NO-3.