Sirolimus-eluting cobalt alloyed stents in treating patients with coronary artery disease: six-month

来源 :中华医学杂志(英文版) | 被引量 : 0次 | 上传用户:Kdx1999
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background The emergence of drug-eluting stents (DES) has dramatically reduced the incidence of in-stent restenosis.This study was conducted to evaluate the safetyand efficacy of sirolimus-eluting cobalt-chrome stents (Firebird 2) for treating patients with coronary artery disease.Methods Sixty-seven patients with de novo or non-stented restenostic coronary lesions were chosen to receive the Firebird 2 stent as the final treatment (Firebird 2 group). Another 49 consecutive patients were implanted with bare cobalt alloyed stents (Driver, Medtronic) withit the previous six months and served as historical controls (control group).Baseline clinical characteristics, angiographic features, procedural results, 30-day, 6-month and 12-month clinical follow-up regarding the occurrence of major adverse cardiac events (MACE), as well as the primary endpoint of late lumen loss at 6-month angiographic follow-up were compared between the two groups.Results The demographic characteristics were similar between the two groups despite more patients in the Firebird 2group who underwent previous percutaneous coronary intervention (22.4% vs 8.2%, P=0.0418) and who had diabetes mellitus (29.9% vs 12.2%, P=0.0253). In the Firebird 2 group, the mean diameter of the reference vessel was smaller((2.79±0.46) mm vs (2.98±0.49) mm, P=0.0175) and more stents were implanted for each lesion (1.28±0.52 vs 1.10±0.30, P=0.0060). Other angiographic, procedural results and the device success rate were similar between the two groups. The MACE rate at 30-day and 3-month was the same, but significantly fewer MACE occurred in the Firebird 2group at 6- and 12-month follow-up (1.5% vs 12.2% at 6 month, P=0.0168; 1.5% vs 26.5% at 12 month, P<0.0001). The primary endpoint of late lumen loss at 6-month angiographic follow-up was significantly reduced in the Firebird 2 group (in-stent: (0.05±0.09) mm vs (0.98±0.61) mm; in-segment: (0.05±0.18) mm vs (0.72±0.59) mm; P<0.0001) than the control group. One patient in the Firebird 2 group had in-segment restenosis (1.3%) while the rate in the control group (38.1%) was significantly higher, P<0.0001. Intravascular ultrasound examination was performed in 70.1% of patients in the Firebird 2 group and revealed that the percentage of volumetric obstruction was (1.26± 1.05) %. No stent thrombosis was observed ineither group at 12-month follow-up.Conclusion The Firebird 2 sirolimus-eluting cobalt alloyed stent is safe and feasible in treating patients with coronary artery disease.
其他文献
AIM:To elucidate the role of Rab23 in hepatocellular carcinoma(HCC)by assessing the expression of Rab23 in HCC tissue and in HCC cell lines.METHODS:Primary tumo
Liposarcoma is the most common soft tissue sarcoma and accounts for 15%-20% of all mesenchymal malignancies. The tumor occurs most frequently in the limbs, retr
介绍了一种利用快速傅里叶变换算法对稀土掺杂物质的荧光寿命进行数据拟合的方法.稀土掺杂物质可用来制备多种光学传感器,用于温度、pH值等多种参量测量领域.本方法利用快速
在为编写伞形科而进行的修订工作中,提出了11个新组合,即矮小丝瓣芹Acronema minus (M. F. Watson) M. F. Watson & Z. H. Pan, 短柄丝瓣芹A. brevipedicellatum Z. H. Pan &
AIM: To investigate the hypothesis that duodenal bulb (DB) inhibition on pyloric antrum (PA) contraction is reflex. METHODS: Balloon (condom)-tipped tube was in
应用小角x射线散射技术研究了大鼠骨质疏松模型的微结构.与正常大鼠的骨结构相比,骨质疏松模型大鼠中的无机矿物质颗粒的比内表面和体积百分数减小.这说明骨质疏松模型大鼠的
AIM:To ifivestigate the influence of heme oxygenase-1(HO-1)gene transfer on the viability and function of cultured rat islets in vitro.METHODS:Islets were isola
Background E-cadherin, beta-catenin, cathepsin D, matrix metalloproteinase (MMP)-2, MMP-9, tissue inhibitors of metalloproteinase (TIMP)-1 and TIMP-2 are all in
AIM:To study the induction of T cellular immune responses in BALB/c mice immunized with uric acid and dendritic cells(DCs)pulsed with hepatitis B virus surface