论文部分内容阅读
为验证此《标准》在试验靶场的适用性,对参加试验的14种武器在发射时进行了压力波测量及暴露人员身体检查,按《标准》规定计算出Lp值,再将实测得的压力波峰值(分贝)与Lp值比较,分为超标组及标准组对比,统计安全保护率。研究结果:即使压力波峰值已达到了Lp值以下,暴露人员的安全保护率也没有达到90%的要求.结论:此《标准》尚不适用试验靶场,需进行修订,以给出适用于靶场的安全标准。
In order to verify the applicability of this “standard” in the test range, 14 participating weapons were tested for pressure wave and physical examination of exposed persons at the time of launching. The Lp value was calculated according to “standard” and then the measured pressure The peak value (decibel) is compared with the Lp value, which is divided into standard group and standard group, and the statistical safety protection rate is calculated. Findings: The safety protection rate for exposed workers did not reach 90% even though the pressure wave peak had reached below the Lp value Conclusion: This “standard” is not yet applicable to the test range and needs to be revised to give a suitable range for the range Safety standards.