喷雾器由药液桶、气筒、喷头、开关等部件组成。在使用中发生的主要故障一般都可以自己排除。现将喷雾器的主要故障及排除方法介绍如下。一、气筒打不进气一般是因皮碗干缩硬化,或磨损破裂所致,也有可能是皮碗底部的螺丝松动脱落,皮碗掉了下来。排除的方法是:将干缩硬化的皮碗拆下来,放进机油或动物油中浸泡,待膨胀后,再重新装上;对磨损破裂的皮碗,已不能再继续使用,可另换上新皮碗;对松动脱落的皮碗底部的螺丝,只要装上皮碗拧紧即可。
Sprayer from the chemical barrels, gas cylinder, nozzle, switches and other components. In the use of the main fault can generally be excluded by their own. Sprayer now the main failure and troubleshooting are described below. First, the cylinder does not enter the gas is generally due to dry shrinkage sclerosis, or wear and tear caused by rupture, it may be the bottom of the screw loose screw off the cup fell off. Exclusion method is: the hardened scallops removed, put into the oil or animal oil soak, to be expanded, and then re-installed; wear broken cup, can no longer continue to use, and the other can be replaced by new Bowl; Loosen the screws on the bottom of the cup bowl, just tighten the bowl can be fitted.