[例1]故障现象 接通电源开关,电源指示灯不亮,带盒插不进。 分析与检修 接通电源开关,电源指示灯不亮,先用500型万用表检查稳压电源输出的ALL5V和ALL12V电压正常,初步判断故障存在带仓机构或系统控制电路中。由带仓机构成系境控制电路造成上述故障现象大致有如下几种原因:①带仓右下方齿轮条与带仓加载臂边缘定位孔错位;②黑色齿轮条与白色齿轮条中间定位销断裂;③CAS SW开关损坏;④徽处理器IC01工作失常。为了迅速确定故障存在的部位,拆开机壳检查带仓加载臂与齿轮条边缘定位孔位置正常,检查齿轮条定位销没有发现异常情况。用万用表检查CAS SW开关,发现开关一端有4.6V电压存在,说明故障存在系统控制电路中,在出盒状态正常条件下,CAS SW开关应处于接通状态,开关管Q02基极通过CAS SW开关按地,说明CAS SW开关电路有问题。卸下CAS SW
[Example 1] Symptom Turn on the power switch, the power light does not light, with the box does not enter. Analysis and Maintenance Turn on the power switch, the power light is off, first check with a 500 multi-meter power supply output ALL5V and ALL12V voltage is normal, the initial judge of the existence of the fault with the system or the control system. The mechanism causing the above fault caused by the control mechanism of the system with the warehouse unit is generally caused by the following reasons: ① the positioning holes on the lower right side of the magazine with the loading edge of the loading arm are misaligned; ② the middle positioning pins of the black gear rack and the white gear rack are broken; ③CAS SW switch is damaged; ④ emblem processor IC01 malfunction. In order to quickly determine the existence of the fault location, open the chassis to check the position of the loading arm arm and gear bar positioning hole location, check the gear bar positioning pin found no abnormalities. Check the CAS SW switch with a multimeter and found there is a voltage of 4.6V at one end of the switch, indicating that the fault exists in the system control circuit. Under the normal conditions of the output box, the CAS SW switch should be in the ON state, the switch Q02 base through the CAS SW switch Press to indicate that there is a problem with the CAS SW switch circuit. Remove CAS SW