对气管内套管进行手工或机械清洗后质量检测发现清洗不彻底,返洗率高,对灭菌质量构成潜在感染隐患。为探求内套管最佳手工清洗方法,于2013年10-12月对神经外科不锈钢气管内套管分别进行了4种手工清洗方法及效果比较。1方法1.1清洗方法将回收后气管内套管按4种方法手工清洗,每种方法至少进行15个工作日,套管清洗检测数每种方法均为135个,记录清洗结果,比较不同方法清洗
Endobronchial tube after manual or mechanical cleaning quality testing found that cleaning is not complete, backwash rate, the potential quality of the hidden infection infection. In order to explore the best manual cleaning method of inner cannula, four kinds of manual cleaning methods and their effects were compared respectively to the stainless steel tracheal cannula of neurosurgical department from October to December in 2013. 1 Method 1.1 Cleaning Method After the recovery of the endotracheal tube manual cleaning by four methods, each method at least 15 working days, the number of casing cleaning test for each method is 135, record the results of cleaning, cleaning more different methods