通过对GCr15钢真空加热淬火和盐浴加热淬火的多次对比试验,研究了真空加热条件下奥氏体化温度和时间对奥氏体实际晶粒度的影响。结果表明,对于GCr15钢,在相同的奥氏体化温度下,当保温系数相同时,真空与盐浴加热后的晶粒大小几乎没有什么差别,在误差范围之内,当真空加热的保温系数4倍于盐浴加热时,其奥氏体晶粒度相差不超过半级;即使真空加热的保温系数12倍于盐浴加热时,前者的奥氏体实际晶粒度也只不过比后者约大一级。因此完全不必担心所谓真空热处理会促使晶粒长大的问题,文中给出了显示GCr15钢奥氏体实际晶粒的较佳浸蚀规范。
The effect of austenitizing temperature and time under vacuum heating on the actual grain size of austenite was studied by comparing several times of GCr15 steel vacuum quenching and salt bath heating quenching. The results show that for the GCr15 steel, at the same austenitizing temperature, when the thermal insulation coefficient is the same, there is almost no difference in the grain size of the vacuum and salt bath after heating. Within the error range, when the thermal insulation coefficient 4 times the salt bath heating, the austenite grain size difference of not more than half; Even if the vacuum heating coefficient of 12 times the temperature of the salt bath heating, the former of the actual grain size of austenite, but only than the latter About a big one. Therefore, there is absolutely no need to worry about the so-called vacuum heat treatment will cause grain growth problem, the text shows the GCr15 steel austenite actual grain better erosion specification.