论文部分内容阅读
中越边境自卫还击战的16天收容中,我们医疗所X线室就为338位伤员照了532张X线片,没有出现废片,一等片达98%以上。未发现错诊、漏诊现象。机器装备一直处于正常工作状态,并在透视下配合临床医生为108名伤员取出异物,顺利地完成工作任务。我们的主要做法和体会如下。一、周密考虑,做好战前准备工作 X线机房的设置:我们利用1个约20平方米的废猪圈布置成X线室,三面围墙只有1米高,我们用竹席、茅草、油毛毯及黑红布围成机房,对砖缝、门角容易漏光的地
During the 16-day shelter of the China-Vietnam self-defensive counterattack, 532 radiographs of 338 wounded people were taken by our X-ray room, with no wastes and no more than 98% of the first-class pieces. No misdiagnosis, missed diagnosis. Machine equipment has been in normal working condition, and under the perspective with the clinician to remove foreign bodies for 108 wounded, successfully completed the task. Our main practices and experiences are as follows. First, careful consideration, do a good job in pre-war preparation X-ray machine room settings: We use a waste of about 20 square meters of pigsty arranged X-ray room, three walls only 1 meter high, we use bamboo mat, thatch, oil Blankets and black and red cloth into the engine room, the brick joints, easy to leak door to the ground