在吐鲁番车站发电所扩建设计过程中,我们感到,按《铁路工程技术规范》的规定确定柴油机发电所设计规模,存在一些问题,我们认为《规范》的有关规定应作一些修改。现结合吐鲁番车站发电所的情况,谈谈我们的看法。由于周围无地方电源,多年来吐鲁番车站一直由柴油发电机组供电。1974年铁道部第一设计院为南疆线作吐鲁番车站扩建设计时,设计了一座柴油机发电所,装机容量520kW(其中一台200kW为备用机组),发电所于1981年建成发电。1980年,铁路局有关部门提出,该所发电容量不能满足车站用电需要,要求扩建。我们查阅了铁一院的设计文件,对吐鲁番车站用电情况作了比较详细的调查。发现:铁一院的设计经过认真调查,并同铁路局有关部门洽商过,计算和设
In the process of expansion design of Turpan station power station, we feel that there are some problems in determining the design scale of diesel engine power station according to the “Technical Specifications for Railway Engineering”. We think some amendments to the relevant provisions of the “Regulation” are needed. Turpan station now combined with the situation of power generation, talk about our views. Turpan Station has been powered by diesel generators for many years due to the lack of local power supply. In 1974, when the First Design Institute of the Ministry of Railways designed the expansion of Turpan Station for the Sijiang Line, a diesel generating station was designed with an installed capacity of 520kW (of which 200kW is a backup unit). The power station was built in 1981 to generate electricity. In 1980, the relevant departments of the Railway Administration proposed that the power generation capacity of the station can not meet the station’s electricity needs and requires expansion. We consulted the iron hospital design documents, made a more detailed investigation of the electricity situation Turpan Station. Found: iron a hospital after careful investigation of the design, and negotiated with the relevant departments of the railway administration, calculation and design