Safety and Efficacy of a Novel Technique in the Use of Fractional Flow Reserve in Complex Coronary A

来源 :第13届中国介入心脏病学大会(CJT2015) | 被引量 : 0次 | 上传用户:yange20092009
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Background: Fractional flow reserve (FFR) has become an increasingly important index when making decisions with respect to revascularization of coronary artery stenosis.However, the pressure guidewire used in obtaining FFR measurements is difficult to control and manipulate in certain complex coronary artery lesions, resulting in increased fluoroscopy time and contrast dye usage.This study examined a novel (NOV) technique for obtaining FFR measurements in hope of easing the difficulties associated with evaluating and treating complex coronary artery lesions.Methods: Fifty-six patients with complex coronary artery lesions were assigned to a conventional (CON) FFR technique group or a NOV FFR technique group.The NOV technique involved the use of a balloon and wire exchange within the coronary artery.The fluoroscopy time, contrast dye usage, and FFR-related complications were assessed after completing the FFR measurement procedure for each patient.Results: The median time required for fluoroscopy in the NOV technique group was significantly less than that in the CON technique group;additionally, lesser amounts of contrast dye were used in the NOV technique group (both P < 0.05).The NOV technique was successfully performed in thirty patients, without any FFR-related complications.However, the CON technique failed in three patients,including two who experienced coronary artery spasms (P > 0.05).Conclusions: Compared to the CON technique used for measuring FFR, the new technique reduced the fluoroscopy time and amount of contrast dye used when evaluating complex coronary artery lesions.The new technique did not increase the risk of operation or decrease the success rate.
其他文献
最近三十年彩色都卜勒超音波机器快速发展及许多学者投入相关疾病研究,使得此一检查能很方便的观察血管及血管疾病的解剖学变化和血流动力学的特性,彩色超音波为非侵袭性的检查方法、不具游离辐射、无需注射显影剂,其中的灰阶超音波影像提供了二维空间多切面的解剖结构变化,彩色流体影像和都卜勒频谱则显示出血流动力学的变化,能实时性探查血管局部血流变化的能力弥补了血管摄影因显影剂注射时导管尖端摆放的部位、注射的时间、
会议
Background: Despite great reduction of in-stent restenosis, first-generation drug-eluting stents (DESs) have increased the risk of late stent thrombosis due to delayed endothelialization.Arsenic triox
Background: Permanent atrial fibrillation (AF) is the most common form of dysrhythmia associated with atrial septal defects (ASDs) in patients older than 40 years.However, little is known about cardia
Background: Several platelet function tests are currently used to measure responsiveness to antiplatelet therapy.This study was to compare two tests, light transmittance aggregometry (LTA) and modifie
Background: Renal sympathetic nerves are involved in the reflective activation of the sympathetic nervous system in circulatory control.Catheter-based renal denervation (RDN) ameliorated treatment-res
Background: Despite the improvement in the health care industry, the rates of undetected, untreated, and uncontrolled hypertension (HTN)are still very high, especially in rural areas of China.The aim
Background: Radial artery (RA) occlusion (RAO) is not rare in patients undergoing coronary intervention by transradial approach (TRCI).Predictors of and prevention from RAO have not been systematicall
Background: Current randomized trials have demonstrated the effects of short-term rosuvastatin therapy in preventing contrast-induced acute kidney injury (CIAKI).However, the consistency of these effe
Background: Complex noise and its relation to hearing loss are difficult to measure and evaluate.In complex noise measurement,individual exposure results may not accurately represent lifetime noise ex
Background: The purpose of this article was to clarify the optimal management concerning transjugular intrahepatic portosystemic shunts (TIPSs) and surgical shunting in treating portal hypertension.Me