搜索筛选:
搜索耗时1.5002秒,为你在为你在102,285,761篇论文里面共找到 11 篇相符的论文内容
类      型:
[期刊论文] 作者:Jung-Chuan Chou,Shen-Kan Hsiung,, 来源:稀有金属材料与工程 年份:2006
The application of Bluetooth on the pH sensor was accomplished.Based on the experimental results,Bluetooth technology was used to measure pH values without limi...
[期刊论文] 作者:Szu-Ping Chen,Jung-Chuan Chou,Shen-Kan Hsiung,, 来源:稀有金属材料与工程 年份:2006
In this paper,the pCO_2 sensitive electrode was studied for continuous measurement.The solid electrolyte membrane and gas-permeable membrane were coated on the...
[期刊论文] 作者:Gin-Chou Yang,Jung-Chuan Chou,Shen-Kan Hsiung,, 来源:稀有金属材料与工程 年份:2006
In this study,the multi-sensing system based on the tin oxide pH electrode for the ion-determination was presented. With the advantages of the real-time supervi...
[期刊论文] 作者:Jui-Fu Cheng,Jung-Chuan Chou,Shen-Kan Hsiung,, 来源:稀有金属材料与工程 年份:2006
This paper presents the studying results of the sodium ion sensor device based on the SnO_2/ITO glass structure in the detection of rinsing solution for contact...
[期刊论文] 作者:Jung-Chuan Chou,Shen-Kan Hsiung,Jui-Hsiang Hsieh,, 来源:稀有金属材料与工程 年份:2006
An amperometric glucose biosensor based on a tin oxide (SnO_2) electrode has been developed.The SnO_2 electrode is prepared by depositing the SnO_2 thin film on...
[期刊论文] 作者:Ching-Han Yu,Jung-Chuan Chou,Shen-Kan Hsiung,, 来源:稀有金属材料与工程 年份:2006
An impedance type humidity sensor based on the polyacrylic emulsion containing magnesium chloride (MgCl_2) without chemical modification was investigated.The i...
[期刊论文] 作者:Nien-Hsuan Chou,Jung-Chuan Chou,Shen-Kan Hsiung,, 来源:稀有金属材料与工程 年份:2006
Enzyme was immobilized on an ammonium ion-selective electrode by different methods.An ion-selective electrode is not completely ion-specific,and interfering ion...
[期刊论文] 作者:Chin-Shuen Hung,Jung-Chuan Chou,Shen-Kan Hsiung,, 来源:稀有金属材料与工程 年份:2006
In this study,tin oxide sensing membrane was derived by sol-gel method and was coated onto indium tin oxide (ITO) glass substrate by spin-coating technique to...
[期刊论文] 作者:Chu-Neng Tsai,Jung-Chuan Chou,Shen-Kan Hsiung,, 来源:稀有金属材料与工程 年份:2006
Drift phenomenon has been known as the drawback of sensors and causes inaccuracy on the long-term measurement. In general,there are two methods to reduce the dr...
[期刊论文] 作者:Chih-Wei Lai,Jung-Chuan Chou,Shen-Kan Hsiung,, 来源:稀有金属材料与工程 年份:2006
Continuous intra-arterial blood gas monitoring is used clinically in hospital and intensive care unit settings.The blood gas can be detected by the colormetric...
[期刊论文] 作者:Chung-We Pan,Jung-Chuan Chou,Shen-Kan Hsiung,, 来源:稀有金属材料与工程 年份:2006
This study reveals the successful design of the data acquisition system for pH sensors.The data acquisition system includes an instrumentation amplifier,a low p...
相关搜索: