基于阳极溶出伏安法原理的便携式重金属检测仪是重金属环境污染事故现场监测的重要手段,可在事故现场对Zn,Cd,Pb,Cu,Hg,As等进行快速定量分析测定。对便携式重金属检测仪现场快速分析方法进行了优化研究,并与实验室分析方法进行了系统比对。优化方法拓宽了定量分析范围,使Cd,Pb,Cu的定量范围调宽到校准点浓度的10%~10倍(即0.02~2.00mg/L);Zn的定量范围调宽到校准点浓度的10%~250%(即0.02~0.50mg/L);Hg的定量范围为达到校准点浓度的20%~2倍(即0.005-0.500mg/L),满足μg/L-mg/L级不同浓度的分析。优化后方法性能数据表明,zn,Cd,Pb,Cu,Hg,As的检出限在6×10^-4~4×10^-2mg/L,RSD小于6%,RE在-18%~20%,基体加标回收率为72%~120%。比对数据显示与实验室标准方法相比,该方法的检出限,与ICP—AES相当,优于AAS火焰法;RSD与其两者相当,准确度略低于此两者,鉴于该方法测定时间短,仪器可便携,更适用于污染事故重金属的现场测定。“,”Portable heavy metal detector basing on Anodic Stripping Voltammetry is one of the convenient means applicable to heavy metals contamination measurement, which can provide immediate quantitative analysis results for Zn, Cd, Pb, Cu, Hg, As and such. In this paper, comparison experiments between standard laboratory analysis methods and rapid field metal detection have been constucted and conducted to improve the accuracy of field metal detection method. The refined methods broadened the detection range, the Cd, Pb, Cu quantitative range extended to 10% to 10 times of the calibration point concentration (0.02 mg/L-2.00 mg/L) ; Zn quantitative range to 10%-250% of the calibration point concentration (0.02 mg/L-0.50 mg/L) ; Hg quantitative range to 20% to 2 times of the calibration point concentration (0. 005 mg/L-0. 500 mg/L), in order to meet the detection limit for various level of sample, concentrations range from μg/L to mg/L. Performance data of optimized method show that the detection limit of Zn, Cd, Pb, Cu, Hg, As is about 6×10 4 -4× 10-3 mg/L, RSD is less than 6%, RE is about- 18%-20%, and the substrate standard addition recovery is within 72%-120%. Comparing with results from standard laboratory analysis methods shows that improved field detection method share a similar detection limit with ICP AES, while has relatively wider detection range than flame AAS method All methods have close RSD value, while the field detection provide slightly less accurate results than the others. All in all, in lights of the its rapid de- tection and portability, the detector is suitable for field heavy metals contamination detection, particularly, during some pollution accidents.
其他文献
21世纪以来,肾脏病专业与急危重症医学专业提出了急性肾损伤(AKI)的概念,其核心在于早期诊断、早期治疗,从而改善预后。AKI的理念也被用于肝硬化患者肾损伤的诊治。AKI是失代偿期肝硬化患者常见并发症之一。肝硬化患者的AKI有其独特之处。AKI严重影响肝硬化患者预后,增加住院率和医疗负担。现简要介绍肝硬化腹水患者AKI及肝肾综合征型AKI的诊断及处理进展。
对皮革鞣制废液采用分步投加FeSO4·7H2O、H2O2法进行预处理,考察了FeSO4·7H2O、H2O2的投加方式与投加量、反应温度、pH值、反应周期等的影响.结果表明,最佳工艺参数为:温度
期刊
@@
目的探讨骨关节炎(osteoarthritis,OA)汉族国人血液白细胞介素(interleukin,IL)-17A G-197A和IL-17F T7488C的基因多态性,分析其与OA易感性之间的关系。方法选取2008年1月至2015年12月因膝关节OA接受全膝关节置换术的OA患者及健康志愿者作为研究对象。采集纳入研究的200例OA患者(OA组)和200例健康志愿者(健康对照组)静脉血,提取DNA
该文从挂篮荷载计算、施工流程、支座及临时固结施工、挂篮安装及试验、合拢段施工、模板制作安装、钢筋安装、混凝土的浇筑及养生、测量监控等方面人手,介绍了S226海滨大桥
目的探讨血清糖链抗原19-9(CA19-9)在胆道系统良恶性疾病鉴别诊断中的临床价值。方法回顾性研究2008年1月至2011年3月在兰州大学第一医院普通外科接受诊治的167例胆道疾病患者临床资料。所有患者均签署知情同意书,符合医学伦理学规定。根据疾病性质将患者分为胆道良性疾病组(良性病组,85例)和胆管癌组(恶性病组,82例)。患者入院后检测血ALT、AST、GGT、ALP、TB、DB、总蛋白(T
该文从挂篮荷载计算、施工流程、支座及临时固结施工、挂篮安装及试验、合拢段施工、模板制作安装、钢筋安装、混凝土的浇筑及养生、测量监控等方面人手,介绍了S226海滨大桥
该文从挂篮荷载计算、施工流程、支座及临时固结施工、挂篮安装及试验、合拢段施工、模板制作安装、钢筋安装、混凝土的浇筑及养生、测量监控等方面人手,介绍了S226海滨大桥
针对近期在变电站发生的一起电动操作隔离开关拉开后自动合上的障碍,为了防止由此造成事故,对电动操作的控制回路进行了详细分析,并提出了对策.