本文研究了催化光度返滴定法测定微量锰的原理,找到最佳实验条件,确立了实验方法。测定波长622nm;反应时间1min40s;活化剂NTA用量0.60mL;KIO4与孔雀石绿用量比为1.00∶0.35;室温下滴定;用pH=5.4的乙酸-乙酸钠缓冲溶液控制溶液酸度;测定Mn2+的浓度范围为1×10-7~1×10-5mol/L;Co2+、Bi3+、Ca2+、Al3+、Pb2+、Cu2+、Zn2+、Fe2+、Mg2+等离子均不干扰测定。该法具有较高灵敏度和准确度。试用于黄豆和化学试剂MgSO4中锰的测定,结果令人满意。
In this paper, the principle of catalytic photometric back titration of trace manganese was studied, the best experimental conditions were found, and the experimental method was established. Determination of wavelength 622nm; reaction time 1min40s; activator NTA dosage 0.60mL; KIO4 and malachite green ratio was 1.00:0.35; titration at room temperature; pH = 5.4 with acetic acid - sodium acetate buffer solution control The concentration of Mn2 + was determined to be 1 × 10-7 ~ 1 × 10-5mol / L. The determination of Co2 +, Bi3 +, Ca2 +, Al3 +, Pb2 +, Cu2 +, Zn2 +, Fe2 + and Mg2 + did not interfere with the determination. The method has high sensitivity and accuracy. The test was applied to the determination of manganese in soybeans and chemical reagent MgSO4, and the results were satisfactory.