非接触散斑干涉法测量高温物体应变的研究

来源 :光学学报 | 被引量 : 0次 | 上传用户:liuweiljfs
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
描述了散斑干涉高温物体应变测试实验装置工作原理及其实验结果。对钨和石墨的测量表明:该装置可实现高温状态下材料应变测试,测试精度达1μm。选择波长632.8nm、半宽2.4nm的窄带滤光片,配之预处理电路,对632.8nm辐射散射能力较强的材料(诸如钨带等)可实现2300℃高温非接触应变测量;对632.8nm辐射散射能力较差的材料(诸如石墨等)可实现1500℃高温非接触应变测量。 Describes the working principle and experimental results of the strain test device for speckle interference high temperature objects. The measurement of tungsten and graphite shows that the device can achieve the material strain test under the condition of high temperature and the testing precision reaches 1μm. Select a narrowband filter with a wavelength of 632.8nm and a half width of 2.4nm with a pretreatment circuit to achieve high temperature non-contact strain measurement of 2300 ℃ for 632.8nm material with strong radiation scattering ability (such as tungsten ribbon) Materials that are less capable of scattering 632.8 nm radiation (such as graphite, etc.) can achieve a high temperature non-contact strain measurement of 1500 ° C.