Public buildings such as libraries consume a vast amount of cooling energy for maintaining a comfortable and stable indoor environment in summer, especially in the hot-humid climate. This study used a case study approach to discuss the effect of low-energy strategies that can be applied to improve indoor thermal environment and cooling energy consumption of library buildings in hot and humid cities like Nanning City (a southern city, China). The use of cooling window shutters (a shutter with the effects of shading and evaporative cooling) and ceiling fans for generating airflow was considered as applicable energy-saving measures in this study, and a university library was selected as the study building in which the two energy-saving measures were employed. The SET* and annual cooling load before and after the adoption of the proposed measures were quantitatively investigated with a building energy consumption simulation software (DesignBuilder). Simulation results showed that the daytime SET* values can be reduced by 3.0 ℃ and 4.5 ℃ respectively on a typical summer day after the use of the cooling shutters and ceiling fans. Moreover, the cooling loads can also be decreased by 8.4% and 16.6% respectively. Particularly, the combination of these two measures enabled the daytime SET* value and annual cooling load lower by 7.0 ℃ and 60.8% respectively.
其他文献
在我国工程建设产业链不断发展的今天,工程建设项目的施工管理需要遵循更多的工程建设规范.众所周知,建筑工程管理和施工质量管理的必要性日益突出,而且已经成为建筑工程施工
进入21世纪以来,我国房地产项目越来越多,房地产工程管理工作十分重要.我国房地产工程在国民经济中的占比越来越大,其市场竞争压力也越来越大,再加上在房地产工程施工过程中
In the Canadian north, the cost of space heating is very high due to the harsh weather, its remoteness, lack of transportation, and dependency on the high cost
随着社会经济的进步发展以及城市化进程的不断加快,建筑行业也得到了迅速的发展,各种新材料、新技术的应用也最大限度上满足了人们对现代建筑的要求.其中施工技术的应用效果,
Evacuation systems in buildings are frequently assessed to improve emergency response processes. This paper proposes a method to evaluate the performance of dif
Due to the different approaches in determining the ventilation airflow rate per person for workspaces, where high-temperature air conditioning systems are used
It is well known that the passive strategies applying in traditional buildings respond satisfactory to climatic requirements and succeed to provide maximum indo
Central air-conditioning systems predominantly operate under partial load conditions. The optimization of a differential pressure setpoint in the chilled water
Numerical studies on internal fire whirls (IFW) generated in a vertical shaft model with a single corner gap were reported in this paper. The generation of IFW,