论文部分内容阅读
[摘要] 本文通过对实际测量所得输入功率的结果进行不确定度评定,排除可能因设备、人员、测量方法、环境及被测物品等不确定因素影响,而导致测量结果的不准确。本文还指出当测试指标处于临界值附近时,正确运用测量不确定度可以降低错判率,提高检验报告结论的准确性,防止错判,造成不良后果,同时也能有效规避实验室的风险。
[关键词] 测量不确定度 临界值 输入功率
[Abstract] This article provides examples of evaluating the uncertainty of measuring results of the electrical parameter’s input power and excludes the possible reasons of equipment, staff, measurement methods, environment and measurand which can cause inaccurate results. In addition, this article also points out that when the measure mark approaches to the critical value, proper use of the measurement uncertainty will minimize the risk of wrong decisions to avoid the economic loss of clients, improve the accuracy of the testing report as well as avoid risk of experimental laboratory.
[Key Words] measurement uncertaintycritical valueinput power
1.概述
输入功率是电子和家电产品的重要指标之一。输入功率过小会直接影响到家电产品的功能和效果,过大又会造成不必要的损耗,浪费资源,甚至会造成安全隐患。通过对检测结果进行测量不确定度评定,有效把握检测结果的准确性。本文以某次监督试验,被测样品电热水壶的额定功率1600W,对其所测输入功率结果进行测量不确定度评定。
1.1测量依据和方法
依据GB 4706.1-2005《家用和类似用途电器的安全 第1部分:通用要求》,规定输入功率偏差:+5%或20W(选较大的值),-10%。在测量环境条件温度:(15~25)℃ 相对湿度:40%~80%下测试。
1.2测量仪器
AN8716P数字式电参数综合测试仪,10kW稳压器。
2.测量方法
2.1测试方法
用AN8716P数字式电参数综合测试仪,并用10kW变压器将输入电压控制在220V±0.5V,重复测量,共记录9次电流、电压和功率因数的实测数据。
2.2测试数据(见表1所示)
2.3根据测试数据求出电流、电压的算数平均值,算得输入功率结果:1438.60W
3.数学模型
应用下式计算被测样品的功率
(1)
4.测量不确定度来源
4.1测量功率的不确定度来源主要包括:
①电流测量重复性引起的不确定度分量,属于A类评定方法。
②电压测量重复性引起的不确定度分量,属于A类评定方法。
③功率因素测量重复性引起的不确定度分量,属于A类评定方法。
④电压测量用标准器引起的不确定度分量,属于B类评定方法。
⑤电流测量用标准器引起的不确定度分量,属于B类评定方法。
⑥功率因素测量用标准器引起的不确定度分量,属于B类评定方法。
5.各相对不确定度分量的灵敏系数
电流、电压及功率因素测量重复性引起的不确定度分量灵敏系数为:
三个由于标准器带来的不确定分量灵敏系数均为1.
6 各标准不确定度分量的评定
6.1电流测量重复性引起的不确定度分量u1的评定
(A) (2)
(A) (3)
在实际情况下通常只作一次测量计算给出,所以以上是单次测量结果不确定度,测量重复性引起的电流测量标准不确定度的分量即是测量结果标准不确定度。
=0.0024(A)
电流的相对标准不确定度为:
6.2电压测量重复性引起的不确定度分量u2的评定
2219.97(V)(4)
(按2.2条中所测9次电压数据求得平均值)
(V)(5)
在实际情况下通常只作一次测量计算给出,所以以上是单次测量结果不确定度,测量重复性引起的电压测量标准不确定度的分量即是测量结果标准不确定度。
=0.094(V)
电压的相对标准不确定度为:
6.3功率因素测量重复性引起的不确定度分量u3的评定
(6)
(7)
在实际情况下通常只作一次测量计算给出,所以以上是单次测量结果不确定度,测量重复性引起的功率因素测量标准不确定度的分量即是测量结果标准不确定度。
功率因素的相对标准不确定度为:
6.4 电压测量标准器准确度引起的不确定度分量的评定
从校准证书上可得电压的相对扩展不确定度为:0.2%,k=2
则电压准确度引起的相对标准不确定度为:
6.5 电流测量标准器准确度引起的不确定度分量的评定
从校准证书上可得电流的相对扩展不确定度为:0.2%,k=2
则电流准确度引起的相对标准不确定度为:
6.6 功率因数测量标准器准确度引起的不确定度分量的评定
从校准证书上可得功率因素的相对扩展不确定度为:0.1%,k=2
则功率因素准确度引起的相对标准不确定度为:
7.计算合成相对标准不确定度
上面已经分析了各种因素引起的不确定度,下面将各种不确定分量合成,由于以上各不确定度分量不相关,所以用方和根法合成相对标准不确定度为:
8.测量结果扩展相对不确定度
取P=95%则k=2
扩展相对不确定度Urel(P)为:
9.测量不确定度报告
P=1438.60 k=2
10.结束语
上述结果测量值落在特定的区间,如果单从电热水壶输入功率偏差值-10.1%(超出试验标准规定值-10%)就判定此项不合格,而不考虑、分析不确定因素的影响,有可能会造成误判,降低报告结果的准确性。通过开展测量结果不确定度评定,提高测量结果的可信性、可比性和可接受性,避免因试验设备、人员、试验方法、环境条件等不同对检测结果引起的差异或争议,避免给企业、消费者、政府和社会造成损失和误导,确保为政府质量监控提供正确信息。同时,也降低实验室风险。
参考文献:
[1]测量不确定度评定与表示JJF1059-1999. [S]
[2]GB 4706.1-2005《家用和类似用途电器的安全 第1部分:通用要求》. [S]
[3]实用测量不确定度评定及案例 中国计量院出版社.
[4]测量不确定度评估和报告通用要求 CNAS-CL07. [S]
作者簡介:
张曙云:(1959—),女,河北人,本科,工程师,湖北省电子信息产品质量监督检验院,研究方向:电子检测质量管理。
[关键词] 测量不确定度 临界值 输入功率
[Abstract] This article provides examples of evaluating the uncertainty of measuring results of the electrical parameter’s input power and excludes the possible reasons of equipment, staff, measurement methods, environment and measurand which can cause inaccurate results. In addition, this article also points out that when the measure mark approaches to the critical value, proper use of the measurement uncertainty will minimize the risk of wrong decisions to avoid the economic loss of clients, improve the accuracy of the testing report as well as avoid risk of experimental laboratory.
[Key Words] measurement uncertaintycritical valueinput power
1.概述
输入功率是电子和家电产品的重要指标之一。输入功率过小会直接影响到家电产品的功能和效果,过大又会造成不必要的损耗,浪费资源,甚至会造成安全隐患。通过对检测结果进行测量不确定度评定,有效把握检测结果的准确性。本文以某次监督试验,被测样品电热水壶的额定功率1600W,对其所测输入功率结果进行测量不确定度评定。
1.1测量依据和方法
依据GB 4706.1-2005《家用和类似用途电器的安全 第1部分:通用要求》,规定输入功率偏差:+5%或20W(选较大的值),-10%。在测量环境条件温度:(15~25)℃ 相对湿度:40%~80%下测试。
1.2测量仪器
AN8716P数字式电参数综合测试仪,10kW稳压器。
2.测量方法
2.1测试方法
用AN8716P数字式电参数综合测试仪,并用10kW变压器将输入电压控制在220V±0.5V,重复测量,共记录9次电流、电压和功率因数的实测数据。
2.2测试数据(见表1所示)
2.3根据测试数据求出电流、电压的算数平均值,算得输入功率结果:1438.60W
3.数学模型
应用下式计算被测样品的功率
(1)
4.测量不确定度来源
4.1测量功率的不确定度来源主要包括:
①电流测量重复性引起的不确定度分量,属于A类评定方法。
②电压测量重复性引起的不确定度分量,属于A类评定方法。
③功率因素测量重复性引起的不确定度分量,属于A类评定方法。
④电压测量用标准器引起的不确定度分量,属于B类评定方法。
⑤电流测量用标准器引起的不确定度分量,属于B类评定方法。
⑥功率因素测量用标准器引起的不确定度分量,属于B类评定方法。
5.各相对不确定度分量的灵敏系数
电流、电压及功率因素测量重复性引起的不确定度分量灵敏系数为:
三个由于标准器带来的不确定分量灵敏系数均为1.
6 各标准不确定度分量的评定
6.1电流测量重复性引起的不确定度分量u1的评定
(A) (2)
(A) (3)
在实际情况下通常只作一次测量计算给出,所以以上是单次测量结果不确定度,测量重复性引起的电流测量标准不确定度的分量即是测量结果标准不确定度。
=0.0024(A)
电流的相对标准不确定度为:
6.2电压测量重复性引起的不确定度分量u2的评定
2219.97(V)(4)
(按2.2条中所测9次电压数据求得平均值)
(V)(5)
在实际情况下通常只作一次测量计算给出,所以以上是单次测量结果不确定度,测量重复性引起的电压测量标准不确定度的分量即是测量结果标准不确定度。
=0.094(V)
电压的相对标准不确定度为:
6.3功率因素测量重复性引起的不确定度分量u3的评定
(6)
(7)
在实际情况下通常只作一次测量计算给出,所以以上是单次测量结果不确定度,测量重复性引起的功率因素测量标准不确定度的分量即是测量结果标准不确定度。
功率因素的相对标准不确定度为:
6.4 电压测量标准器准确度引起的不确定度分量的评定
从校准证书上可得电压的相对扩展不确定度为:0.2%,k=2
则电压准确度引起的相对标准不确定度为:
6.5 电流测量标准器准确度引起的不确定度分量的评定
从校准证书上可得电流的相对扩展不确定度为:0.2%,k=2
则电流准确度引起的相对标准不确定度为:
6.6 功率因数测量标准器准确度引起的不确定度分量的评定
从校准证书上可得功率因素的相对扩展不确定度为:0.1%,k=2
则功率因素准确度引起的相对标准不确定度为:
7.计算合成相对标准不确定度
上面已经分析了各种因素引起的不确定度,下面将各种不确定分量合成,由于以上各不确定度分量不相关,所以用方和根法合成相对标准不确定度为:
8.测量结果扩展相对不确定度
取P=95%则k=2
扩展相对不确定度Urel(P)为:
9.测量不确定度报告
P=1438.60 k=2
10.结束语
上述结果测量值落在特定的区间,如果单从电热水壶输入功率偏差值-10.1%(超出试验标准规定值-10%)就判定此项不合格,而不考虑、分析不确定因素的影响,有可能会造成误判,降低报告结果的准确性。通过开展测量结果不确定度评定,提高测量结果的可信性、可比性和可接受性,避免因试验设备、人员、试验方法、环境条件等不同对检测结果引起的差异或争议,避免给企业、消费者、政府和社会造成损失和误导,确保为政府质量监控提供正确信息。同时,也降低实验室风险。
参考文献:
[1]测量不确定度评定与表示JJF1059-1999. [S]
[2]GB 4706.1-2005《家用和类似用途电器的安全 第1部分:通用要求》. [S]
[3]实用测量不确定度评定及案例 中国计量院出版社.
[4]测量不确定度评估和报告通用要求 CNAS-CL07. [S]
作者簡介:
张曙云:(1959—),女,河北人,本科,工程师,湖北省电子信息产品质量监督检验院,研究方向:电子检测质量管理。