Validation of Doppler Wind Lidar during Super Typhoon Lekima (2019)

来源 :地球科学前沿 | 被引量 : 0次 | 上传用户:mi33123
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
This study undertook verification of the applicability and accuracy of wind data measured using a WindCube V2 Doppler Wind Lidar (DWL).The data were collected as part of a field experiment in Zhoushan,Zhejiang Province (China),which was conducted by Shanghai Typhoon Institute of China Meteorological Administration during the passage of Super Typhoon Lekima (2019).The DWL measurements were compared with balloon-borne GPS radiosonde (GPS sonde) data,which were acquired using balloons launched from the DWL location.Results showed that wind speed measured by GPS sonde at heights of< 100 m is unreliable owing to the drift effect.Optimal agreement (at heights of> 100 m)was found for DWL-measured wind speed time-averaged during the ascent of the GPS sonde from the ground surface to the height of 270 m (correlation coefficient:0.82;root mean square (RMS):2.19 m·s-1).Analysis revealed that precipitation intensity (PI) exerts consider-able influence on both the carrier-to-noise ratio and the rate of missing DWL data;however,PI has minimal effect on the wind speed bias of DWL measurements.Specifically,the rate of missing DWL data increased with increasing measurement height and PI.For PI classed as heavy rain or less (PI < 12 mm·h-1),the DWL data below 300 m were considered valid,whereas for PI classed as a severe rainstorm (PI > 90 rnm·h-1),only data below 100 m were valid.Up to the height of 300 m,the RMS of the DWL measurements was nearly half that of wind profile radar(WPR) estimates (4.32 m·s-1),indicating that DWL wind data are more accurate than WPR data under typhoon conditions.
其他文献
As one of the most devastating tropical cyclones over the western North Pacific Ocean,Super Typhoon Lekima (2019) has caused a wide range of heavy rainfall in China.Based on the CMA Multi-source merged Precipitation Analysis System (CMPAS)-hourly data set
电容式电压互感器(capacitor voltage transformer,CVT)的测量稳定性受周围环境的影响,会在实际电压测量过程中产生误差.为了避免该电压测量误差,提出一种基于循环神经网络(recurrent neural network,RNN)的在线辅助CVT电压测量方法.根据电力系统过去的电压历史数据,利用RNN预测未来某个时间段的电压值,并通过比较预测值与CVT实际测出的真实值来判断CVT的测量稳定性.仿真试验验证了学习率和神经元个数对RNN算法性能的影响,并且与传统的ARIMA(auto
神经导管(nerve guidance conduit,NGC)的通道数越多则越有利于神经再生,但受到技术和成本的限制,目前的多通道神经导管一般少于10个通道.为了制备通道数较多的NGC,采用边长10 cm的立方体铁架、直径0.15 mm的水溶性维纶纱线和直径3 mm的塑料空心管搭建一种牺牲模板,并结合冷冻干燥法制备直径为(2.70±0.30)mm、NGC长度大于2 cm、通道数约20个、内通道直径为(0.13±0.03)mm且通道之间存在孔结构的聚己内酯(polycaprolactone,PCL)多通道
针对异形截面立体编织工艺中存在的锭子干涉问题,提出一种判断轨道设计和锭子排布是否产生干涉的方法.基于三维旋转编织原理和图论理论中确定有向简单回路的方法,通过搜索简化后的轨道网络交点邻接矩阵,快速确定轨道的所有有向简单回路,同时利用锭子排布序列和轨道包含叶轮槽口总数的配合关系,检验轨道设计的合理性,并在此研究基础上结合叶轮等效规则,拓展出一种简易锭子轨道设计方法.研究结果对异形截面立体编织物锭子轨道设计具有指导意义.
There were significant discrepancies in the intensity estimations of Super Typhoon Lekima (2019)among the China Meteorological Administration (CMA),the United States Joint Typhoon Warning Center (JTWC),and the Japan Meteorological Agency (JMA) data sets,w
期刊
The predictions for Super Typhoon Lekima(2019) have been evaluated from official forecasts,global models,regional models and ensemble prediction systems(EPSs) at lead times of 1-5 days.Track errors from most deterministic forecasts are smaller than their
In this paper,a revised method for typhoon precipitation probability forecast,based on the frequency-matching method,is developed by combining the screen-ing and the neighborhood methods.The frequency of the high-resolution precipitation forecasts is used
为准确快速地检测出线粒体DNA拷贝数,建立新型多重荧光定量PCR(polymerase chain reaction)方案.该方案以高拷贝基因(300拷贝)替代以往单拷贝基因作为内参,减小线粒体拷贝数与内参基因拷贝数差异,同时,该方案在单管中检测线粒体和内参基因的拷贝数,消除了在不同管中检测内参基因和目的基因时的孔间差.此外考察了不同DNA抽提方法对线粒体DNA拷贝数检测结果的影响,并且构建质粒标准品(含有内参基因和线粒体DNA区段).采用该方案检测100例中国人外周血样本线粒体DNA拷贝数,发现线粒体D
Gaofen-3 (GF-3) is the first Chinese space-borne multi-polarization synthetic aperture radar (SAR)instrument at C-band (5.43 GHz).In this paper,we use data collected from GF-3 to observe Super Typhoon Lekima(2019) in the East China Sea.Using a VH-polarize
Calibration error is one of the primary sources of bias in echo intensity measurements by ground-based radar systems.Calibration errors cause data discontinuity between adjacent radars and reduce the effectiveness of the radar system.The Global Precipitat