论文部分内容阅读
针对山西阳泉第二发电厂300MW机组W型火焰锅炉存在的过热器超温、飞灰含碳量高、结渣等问题,进行了以二次风配风试验为主要内容的锅炉燃烧调整,通过在不同工况下检测炉内火焰温度分布等锅炉运行参数,分析了各主要二次风对锅炉炉内燃烧工况的影响及其调节规律,并讨论了锅炉负荷变化时对炉内温度分布和配风的影响。图6表2参1
In view of the overheating of the superheater, the high carbon content of fly ash and the slagging in the W-type flame boiler of the 300MW unit of Shanxi Yangquan No.2 Power Plant, the boiler combustion adjustment with the secondary air distribution test as the main content was adopted, The boiler operating parameters such as the temperature distribution of the flame in the furnace were detected under different operating conditions. The influence of each secondary secondary air on the combustion conditions in the boiler and its regulation were analyzed. The effects of the boiler temperature on the temperature distribution and With the impact of the wind. Figure 6 Table 2 Reference 1