论文部分内容阅读
本文通过对监督检验中的一个检验案例的分析加深对TSG T7001-2009《电梯监督检验和定期检验规则—曳引与强制驱动电梯》(以下简称《新检规》)中3.2项和3.16项的理解,同时提出了应注意的问题。1案例分析2010年,在福州某房地产公司的一个楼盘12台额定载重量800kg额定速度1.0m/s电梯。做空载轿厢提升试验时,当对重完全压缩在缓冲器上,在顶层测出
This article deepens the analysis of a test case in supervision and inspection of TSG T7001-2009 “Elevator Supervision, Inspection and Periodic Inspection Rules - Traction and Forced Drive Elevator” (hereinafter referred to as “the new regulations”) in 3.2 and 3.16 Understand, at the same time put forward should pay attention to the problem. Case Study In 2010, a real estate company in Fuzhou, a real estate 12 units rated load 800kg rated speed 1.0m / s elevator. Empty car lift test, when the full weight of the compression in the buffer, measured at the top