邹县发电厂 3台高压加热器有时会发生泄漏。为保障机组的安全 ,泄漏后必须停机检修 ,因此 ,必须将热态下的高压加热器快冷至冷态。只要控制高压加热器的温升率在 1.9℃ /min以下 ,温度的变化对高压加热器寿命影响很小。因此 ,高压加热器的快冷在理论上是完全可行的。邹县发电厂 2号机组应用快冷技术 ,停机后 4h即可对高压加热器进行维修。
Zouxian Power Plant 3 high-pressure heaters sometimes leak. In order to protect the safety of the unit, it is necessary to shut down for maintenance after the leakage. Therefore, the high-pressure heater in the hot state must be rapidly cooled to the cold state. As long as the control of the high-pressure heater temperature rise rate of 1.9 ℃ / min or less, the temperature changes have little effect on the life of high-pressure heaters. Therefore, the rapid cooling of high-pressure heaters is theoretically feasible. Zouxian Power Plant Unit 2 fast cooling technology, 4h after shutdown can be carried out on the high-pressure heater repair.