论文部分内容阅读
为了探讨新型侧管式抗荷服(NKH)、代偿服(NDC)及抗调器(NKT)的抗荷性能,对10名被试者进行了体表压传递性能实验,并对9名被试者进行了离心机生理实验。结果表明,NDC的大腿导压效率明显高于DC4代偿服(P<0.01),但NKH的小腿导压效率明显低于KH4抗荷服(P<0.01);NKH的腹囊下体表压明显高于KH4抗荷服(P<0.01),而NDC的腹囊下体表压明显低于DC4代偿服(P<0.01);NKH、NDC配NKT的抗荷效果分别为2.15G和2.05G,配KT7A抗调器的抗荷效果分别为1.85G和1.75G,均高于KH4抗荷服、DC4代偿服配KT7A抗调器的抗荷效果;NKH、NDC能明显降低G作用下的心率,增加心脏储备。
In order to explore the anti-charge performance of the new type of NKH, NDC and NKT, 10 subjects were tested on the surface pressure transmission performance, and 9 Subjects were centrifuged physiological experiments. The results showed that the thigh pressure of NDC was significantly higher than that of DC4 compensated service (P <0.01), but the leg pressure efficiency of NKH was significantly lower than that of KH4 (P <0.01). (P <0.01), while the surface pressure of NDC was significantly lower than that of DC4 (P <0.01); NKH , NDC with NKT anti-Dutch effect were 2.15G and 2.05G, with KT 7A resistance regulator anti-Dutch effect were 1.85G and 1.75G, were higher than the KH 4 anti-Dutch service, DC 4 compensated KT 7A anti-tone device with anti-load effect; NKH, NDC can significantly reduce the heart rate under the action of G, increase heart reserve.