Colorectal neoplasm:Magnetic resonance colonography with fat enema-initial clinical experience

来源 :World Journal of Gastroenterology | 被引量 : 0次 | 上传用户:gcj820305
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
AIM:To assess Magnetic resonance colonography with fat enema as a method for detection of colorectal neoplasm. METHODS:Consecutive twenty-two patients underwent MR colonography with fat enema before colonoscopy. T1-weighted three-dimensional fast spoiled gradient- echo with inversion recovery sequence was acquired with the patient in the supine position before and 75 s after Gadopentetate Dimelumine administration.Where by,pre and post MR coronal images were obtained with a single breath hold for about 20 s to cover the entire colon.The quality of MR colonographs and patients’tolerance to fat contrast medium was investigated.Colorectal neoplasms identified by MR colonography were compared with those identified on colonoscopy and sensitivity of detecting the lesions was calculated accordingly. RESULTS:MR colonography with fat enema was well tolerated without sedation and analgesia.120 out of 132 (90.9%)colonic segments were well distended and only 1(0.8%)colonic segment was poor distension.After contrast enhancement scan,mean contrast-to-noise ratio(CNR)value between the normal colonic wall and lumen was 18.5±2.9 while mean CNR value between colorectal neoplasm and lumen was 20.2±3.1.By Magnetic resonance colonography,26 of 35 neoplasms (sensitivity 74.3%)were detected.However,sensitivity of MRC was 95.5%(21 of 22)for neoplasm larger than 10 mm and 55.6%(5 of 9)for 5-10 mm neoplasm. CONCLUSION:MR colonography with fat enema and T1-weighted three-dimensional fast spoiled gradient- echo with inversion recovery sequence is feasible in detecting colorectal neoplasm larger than 10 mm. AIM: To assess Magnetic resonance colonography with fat enema as a method for detection of colorectal neoplasm. METHODS: Consecutive twenty-two patients underwent MR colonography with fat enema before colonoscopy. T1-weighted three-dimensional fast spoiled gradient- echo with inversion recovery sequence was acquired with the patient in the supine position before and 75 seconds after Gadopentetate Dimelumine administration. There by, pre and post MR coronal images were obtained with a single breath hold for about 20 seconds to cover the entire colon. The quality of MR colonographs and patients’tolerance to fat contrast medium was investigated. Colorectal neoplasms identified by MR colonography were compared with those identified on colonoscopy and sensitivity of detecting the lesions was calculated accordingly. RESULTS: MR colonography with fat enema was well tolerated without sedation and analgesia.120 out of 132 (90.9%) colonic segments were well distended and only 1 (0.8%) colonic segment was poor distens ion. After contrast enhancement scan, mean contrast-to-noise ratio (CNR) value between the normal colonic wall and lumen was 18.5 ± 2.9 while mean CNR value between colorectal neoplasm and lumen was 20.2 ± 3.1. Bi Magnetic resonance colonography, 26 of Sensitivity of MRC was 95.5% (21 of 22) for neoplasm larger than 10 mm and 55.6% (5 of 9) for 5-10 mm neoplasm. CONCLUSION: MR colonography with fat enema and T1-weighted three-dimensional fast spoiled gradient-echo with inversion recovery sequence is feasible in detecting colorectal neoplasm larger than 10 mm.
其他文献
水平性共转性斜视矫正术为临床上常见手术。但手术时移动水平眼肌的数量,尚有不同的算法,兹将我院通常使用的计算方法及其疗效,作一统计分析;对象和计算方法对象:系我院1972
在VRP理论的基础上,分析了制造系统变化性与柔性、变化性与成本的关系,得出了相应的结论;另外对现有VRP的变化性评估指数体系进行了分析,提出零件产出率和工艺产出率的计算方法,并提出了
Standards are essential to productivity,economic stability, and trade.Standards are the means to reliable product performance and consumer confidence; they serv
新生儿、婴幼儿和儿童的声带麻痹临床上少见,在病因和处理方法上与成年人声带麻痹不同。由于小儿声带麻痹常同时伴有其它系统的先天畸形,故容易漏诊和被忽视,在诊断和治疗方
随着电子计算机时代的兴起,在医疗系统中的广泛应用,由计算机控制的自动视野计也应运而生。它的诞生是视野计划时代的变革,对眼科诊断水平的提高,尤其是对青光眼视野方面的
<正> 目前全国各地青少年学生中视力低下者所占的比例很高,而其中很大一部分表现为近视状态。倘再仔细鉴别,就会发现,这些近视者中有真性和假性近视两种类型,这是两大类性质
各位专家:新年好!中国解剖学会第32届(2016年)学术年会拟定于2016年8月6日-8日在山东济南召开。现将临床解剖学有关征稿事宜通知如下,望各位专家积极投稿及参会。1.征文内容
鸡西矿业集团公司张辰煤矿西三采区3
期刊
1.蓄电池因存电不足导致电解液密度下降时不能添加稀硫酸蓄电池在使用中,电解液中的硫酸并没有消耗,只是随着放电的进行,逐渐转移到两极板上,使电解液密度下降。放电越多,电解液密度