脉冲式硬膜外自控镇痛对剖宫产术后宫缩痛护理的影响

来源 :中国实用护理杂志 | 被引量 : 0次 | 上传用户:xuwei800
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
目的:观察脉冲式硬膜外自控镇痛对剖宫产术后宫缩痛的镇痛效果及护理干预。方法:选取解放军中部战区总医院2019年1—3月择期行剖宫产手术术后均自愿使用硬膜外自控镇痛产妇100例为研究对象,采用随机平行对照试验,将100例研究对象平均分为观察组和对照组,每组50例,对照组采用恒速式硬膜外自控镇痛,观察组采用脉冲式硬膜外自控镇痛,观察2组镇痛效果,同时对2组进行模拟试验,记录背景剂量与追加剂量,2组泵出药液的速度、时间及浸润的面积;记录2组术后6、12、24、48 h切口痛及宫缩痛视觉模拟量表(VAS)评分;记录2组术后当天、术后第1天、术后第2天单次按压后宫缩痛VAS评分,运动阻滞评分;记录2组术后2 d内镇痛泵按压次数、镇痛不全干预次数以及恶心呕吐、皮肤瘙痒、下肢麻木等不良反应发生情况。结果:模拟试验显示1、5 min浸润面积观察组和对照组分别为(130.00 ± 14.14)、(334.00 ± 2.83)cmn 2和(65.00 ± 7.07)、(137.50 ± 3.54)cmn 2,差异有统计学意义(n t值为5.814、61.376,n P<0.05或0.01);观察组术后6、12 h切口痛VAS评分分别为(2.36 ± 1.05)、(2.42 ± 0.95)分,均低于对照组的(3.52 ± 1.09)、(3.16 ± 1.25)分,差异有统计学意义(n t值为5.425、3.331,n P<0.01);观察组术后6、12、24 h宫缩痛VAS评分分别为(3.92 ± 1.14)、(3.84 ± 1.18)、(2.48 ± 1.05)分,均低于对照组的(4.56 ± 1.42)、(4.34 ± 1.30)、(3.80 ± 1.54)分,差异有统计学意义(n t值为2.489、2.008、5.004,n P<0.01或0.05);观察组术后当天、术后第1天、术后第2天单次按压后宫缩痛VAS评分分别为(2.66 ± 0.80)、(2.23 ± 0.68)、(2.22 ± 0.71)分,均低于对照组的(5.14 ± 1.05)、(4.48 ± 0.71)、(3.36 ± 0.80)分,差异有统计学意义(n t值为13.296、15.536、7.534,n P<0.01);观察组术后2 d内镇痛泵按压次数、镇痛不全干预次数分别为(2.28 ± 1.36)、(0.90 ± 0.61)次,均低于对照组的(4.62 ± 1.61)、(0.62 ± 0.53)次,差异有统计学意义(n t值为7.847、2.439,n P<0.01或0.05);观察组产妇满意度评分(5.92 ± 1.37)分,优于对照组的(2.34 ± 0.82)分,差异有统计学意义(n t值为15.856,n P<0.01);观察组不良反应如下肢麻木、恶心呕吐、皮肤瘙痒发生率分别为2.00%(1/50)、4.00%(2/50)、4.00%(2/50),均低于对照组的14.00%(7/50)、16.00%(8/50)、18.00%(9/50),差异有统计学意义(n χ2值为4.759、4.000、5.005,n P<0.05)。n 结论:脉冲式硬膜外自控镇痛能有效降低剖宫产术后宫缩痛,配合积极的护理干预加快了产妇术后康复,值得在剖宫产术后镇痛中推广。“,”Objective:To observe the analgesic effect and nursing intervention of pulse epidural controlled analgesia on uterine contraction pain after cesarean section.Methods:A total of 100 cases of parturient with patient-controlled epidural analgesia after elective cesarean section in Central Theater General Hospital of the Chinese People's Liberation Army from January to March 2019 were selected as study subjects, and 100 cases were divided into observation group and control group, each group of 50 cases, the control group used constant speed epidural patient-controlled analgesia, the observation group used pulse epidural patient-controlled analgesia. The analgesic effect of uterine contraction pain after cesarean section was observed, at the same time, the two groups conducted a simulation test, the speed, time and infiltration area of the pumping liquid were recorded, and the Visual Analogue Scale (VAS) scores of incision pain and uterine contraction pain were recorded at 6 h, 12 h, 24 h and 48 h postoperatively. VAS score of contraction pain after single press, Motor Block score of iatrogenic uterine pain were recorded on the postoperative day, the first day and the second day after operation.The times of additional dose compression by analgesia pump, the times of incomplete analgesia intervention, nausea and vomiting, skin itching and other adverse reactions were recorded within 2 days after operation.Results:The infiltration area at 1, 5 min were (130.00±14.14), (334.00±2.83) cmn 2 in the observation group and (65.00±7.07), (137.50±3.54) cmn 2 in the control group, there were significant differences between the two groups(n t values were 5.814, 61.376, n P< 0.05 or 0.01). VAS scores of incision pain at 6 h and 12 h after operation were (2.36±1.05) and (2.42±0.95) in the observation group and (3.52±1.09) and (3.16±1.25) in the control group, respectively, there were significant differences between the two groups(n t values were 5.425, 3.331, n P<0.01). VAS scores of uterine contraction pain at 6,12 and 24 hours after operation were (2.66±0.80), (2.23±0.68), (2.22±0.71) in the observation group and (5.14±1.05), (4.48±0.71), (3.36±0.80) in the control group, respectively, there were significant differences between the two groups(n t values were 2.489, 2.008, 5.004, n P<0.01 or 0.05).VAS scores of contraction pain after single press on the postoperative day, the first day and the second day after operation in the observation group were (2.66±0.80), (2.23±0.68), (2.22±0.71) in the observation group and (5.14±1.05), (4.48±0.71), (3.36±0.80) in the control group, respectively, there were significant differences between the two groups(n t values were 13.296,15.536, 7.534, n P<0.01). The times of pressing and intervention were (2.28±1.36) and (0.90±0.61) in the observation group and (4.62±1.61), (0.62±0.53) in the control group, respectively, there were significant differences between the two groups(n t values were 7.847, 2.439, n P<0.01 or 0.05). Maternal satisfaction score was (5.92±1.37) and (2.34±0.82) in the observation group and the control group, there was significant difference (n t value was 15.856, n P<0.01).The incidence of adverse reactions such as lower limb numbness, nausea and vomiting and skin pruritus in the observation group were 2.00%(1/50), 4.00%(2/50) and 4.00%(2/50) respectively, which were lower than those in the control group 14.00%(7/50), 16.00%(8/50), 18.00%(9/50), the difference was statistically significant (n χ2 values were 4.759, 4.000, 5.005, n P<0.05).n Conclusions:The pulse epidural controlled analgesia can effectively reduce the uterine contraction pain after cesarean section, and the active nursing intervention can accelerate the postoperative recovery of parturient.
其他文献
本文研制了一种具有“存储一氧化”双功能的Ag-MnOx-CeO2催化剂。在存储阶段,利用催化剂的部分氧化性能,在室温下将低浓度的甲醛富集并将其部分氧化为甲酸盐存储在催化剂上;在
10月21日至25日,由山西省商务厅、省特产贸易促进会共同主办的首届中国(山西)特色产业博览会在山西省展览馆盛大举行“。特博会”以“物华天宝,丰腴山西”为主题,旨在弘扬山
我国幅员辽阔,从北域到南疆纵横数千公里,大量调查资料表明,学生的生长发育水平和月经初潮存在着明显的地区差异。为探讨女学生月经初潮地区差异的规律性,作者收集了我国各
本文使用溶胶一凝胶法合成LaMn03钙钛矿催化剂。催化评价在固定床式反应器上进行,空速为10000ml·g-1·h-1。经过XRD测试结果表明:合成出的LaMnO3为六方晶系,为PDF#32-0484一致
一个是艳丽四射的世界模特冠军,一个是万人瞩目的央视春晚总导演。自从马艳丽和郎昆牵手走上红地毯,便在名人明星圈子中被公认为“郎才女貌”的“天仙配”。然而,很少有人知
本文提出一种基于表面活性剂自组装的作用实现纳米氧化钦在粘土表面的固定化新方法:即在氧化钛溶胶凝胶溶液中引入分散剂制备高度分散的纳米TiO2分散液,再通过表面活性剂在纳
为去除水中氯酚类污染物,用纳米碳酸钙沉积形成动态膜,被作为提高过滤精度、回收催化剂和保护有机膜的无机惰性滤饼层,却发现该动态膜吸附和提高光催化降解去除二氯酚污染物
根据计算机数值模拟的研究方法具有耗时少、成本低、能可视化分析等特点,本文运用Moss模型和Nagle模型对氧化区内碳烟的形成和氧化过程进行多维非稳态数值模拟.结果表明:裂解
本文介绍了一种经氨基甲酸酯高效合成二苯甲烷二异氰酸酯MDI的短流程工艺,具体研究了苯胺和甲醛为原料进行甲基化反应合成MDA的工艺条件。利用高效液相色谱(HPLC)建立了该体系