AO–MW–PLS method applied to rapid quantification of teicoplanin with near-infrared spectroscopy

来源 :JournalofInnovativeOpticalHealthSciences | 被引量 : 0次 | 上传用户:yijixu
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Teicoplanin (TCP) is an important lipoglycopeptide antibiotic produced by fermenting Acti-noplanes teichomyceticus. The change in TCP concentration is important to measure in the fermentation process. In this study, a reagent-free and rapid quantification method for TCP in the TCP–Tris–HCl mixture samples was developed using near-infrared (NIR) spectroscopy by focusing our attention on the fermentation process for TCP. The absorbance optimization (AO) partial least squares (PLS) was proposed and integrated with the moving window (MW) PLS, which is called AO–MW–PLS method, to select appropriate wavebands. A model set that includes various wavebands that were equivalent to the optimal AO–MW–PLS waveband was proposed based on statistical considerations. The public region of all equivalent wavebands was just one of the equivalent wavebands. The obtained public regions were 1540–1868 nm for TCP and 1114–1310 nm for Tris. The root-mean-square error and correlation coefficient for leave-one-out cross validation were 0.046 mg mL 1 and 0.9998 mg mL 1 for TCP, and 0.235 mg mL 1 and 0.9986 mg mL 1 for Tris, respectively. All the models achieved highly accurate prediction effects, and the selected wavebands provided valuable references for designing specialized spectrometers. This study provided a valuable reference for further application of the proposed methods to TCP fermentation broth and to other spectroscopic analysis fields.
其他文献
对于弱吸收薄腹,当薄膜和基底的折射率在一定数值范围内时,含有吸收比的公式可以用来计算薄膜的消光系数.该式不能用来计算已经没有干涉效应的厚的强吸收膜的消光系数.
提出了应用于光刻机照明系统照明光场均匀性的高精度校正方法,该方法通过优化手指阵列式均匀性校正器中校正手指前端的形状及其排布方式来提高校正能力和精度。仿真结果表明:当校正手指错开排布时,手指阵列式均匀性校正器的校正精度优于0.2%;当校正手指的前端有倒斜角且双层错开排布时,手指阵列式均匀性校正器的校正精度优于0.16%,比常规手指阵列式均匀性校正器的校正精度提高约一倍。
Many papers have been published on the theory of magnetic insulation and the use of Zflow analysis of magnetically insulated transmission lines (MITLs). We describe herein a novel design process using the circuit code SCREAMER for
期刊
A 100-Gb/s high-speed optical transmitter is proposed and experimentally demonstrated. Based on frequency-quadrupling technique, two sub-channels with a fixed 50-GHz spacing are obtained from one laser source. Using return-to-zero differential quadrature
结合同轴X射线相位衬度成像(XPCI)中的Born近似相位恢复法和CT技术,实现了基于单一物像距同轴X射线相位衬度CT(IL-XPCT)投影图像的相位恢复切片重构方法。利用上海光源X射线成像及生物医学应用光束线站的单色光开展模型和生物样品(蝗虫)IL-XPCT研究。对比显示,进行相位恢复后,能获得更好的IL-XPCT重构切片和三维重建图像。实验结果表明,本方法具有用于生物活体样品三维无损成像研究的
在超高真空的条件下,测量了清洁、自由银表面产生的光学二次谐波随基波电矢量与入射面之间夹角(?)的变化,从而通过理论公式,求得由Rudnick和Stern引入的,用于衡量垂直面电流密度的唯象参数a的值,在入射基频光波长为1.064μm时,被测定为-4.0±0.8.
We constructed a flexible gold-polydimethylsiloxane (gold-PDMS) nanocomposites film with controllable thickness and light transmittance, to realize optically-excited simultaneous photoacoustic (PA) and ultrasound (US) imaging under a single laser pulse ir
期刊
一月十日至十二日在美国新奥尔良召开的第三届年会上,美国激光医学及外科协会组织了盛会,签到与会者有340多位,有15个商业性展出和一套内容丰富的资料。有121位美国和加拿大的医生,18位他国医生,50位其他方面的医生在会上登记注册, 43位研究工作者,6位兽医以及86位工业界代表,加上护士、技术人员和其他人员出席了会议。发言者报告了几个出自可控试验的临床研究和基础研究的成果。
期刊