水界碑水电站处于地震活跃带及山体易滑坡、易洪涝、易泥石流区域,并经历了2008年5月12日的汶川地震及2010年8月12日至14日的泥石流灾情。水界碑水电站原有技术供水方式为2台卧式离心泵从尾水间接取水后,经滤水器送至机组的发电机空冷器及轴承。该取水方式受下游尾水水质影响较大,通过业主的介绍,该种取水方式严重影响到了水电站的正常稳定运行和电站的综合经济效益。现通过技术改造,在尽量利用原有设备及布置的前提下,采用循环水系统进行供水。投入运行后,机组因水质原因停机而停机的情况不再发生,年利用小时数明显提高,经济效益显著,且机组运行稳定。
Water boundary pillar hydropower station is located in the seismic active zone and the mountain landslide, easy flood, easy debris flow area, and experienced the Wenchuan earthquake on May 12, 2008 and the mudslides disaster on August 12-14, 2010. Water boundary pillar hydropower station of the original technology for two horizontal centrifugal pump water from the tail water, the water filter sent to the generator air cooler and bearings. The way of taking water is greatly influenced by the downstream tail water quality. Through the introduction of the owner, this kind of water intake has seriously affected the normal and stable operation of the hydropower station and the comprehensive economic benefits of the hydropower station. Now through technological innovation, make the best use of the original equipment and layout under the premise of using recycled water system for water supply. After put into operation, the unit stopped down due to water quality reasons and the situation no longer occur, the number of hours of use significantly increased, significant economic benefits, and the unit stable operation.