在检验电梯时,一般情况下检验人员都是用人眼来判断缓冲器复位时间的,这时都需要检测人员蹲在电梯轿厢坑底,这样对检验人员来说环境是很差的,而且又是很危险,检测结果也是很不准确的。本文就介绍一实用方便的电梯缓冲器测试仪传感器的电路,它利用光电开关来检测轿厢和缓冲器脱离信号,进而得到触发电压,并且通过外接555斯密特触发器来转换电平,然后通过接口把信号送进微处理器来判断缓冲器复位时间。
In the inspection of the elevator, under normal circumstances, inspectors are used to determine the buffer reset time, when testing personnel need to squat at the bottom of the elevator car so that the inspectors environment is very poor, and Is very dangerous, the test result is very inaccurate. This article describes a practical and convenient elevator buffer tester sensor circuit, which uses the photoelectric switch to detect the car and the buffer from the signal, and then get the trigger voltage, and the external 555 Schmitt trigger to convert the level, and then Through the interface signal sent to the microprocessor to determine the buffer reset time.