我矿风井使用的B4—72—11型离心式通风机,反风时采用人工操作,完成一次反风需40分钟,不符合《煤矿安全规程》规定的10分钟内完成反风的标准。针对这一问题,我们自行设计挡风闸门和反风启闭装置,使用二年来,效果良好,一次反风时间仅用3分20秒,保证了安全生产。 一、原通风机反风结构存在的问题 1.采用两个厚为6mm的圆形钢板为风机切换挡风闸门,由于钢板薄,受风压后容易变形,致使闸门上提下落不便,影响反风的顺利进行。 2.用圆形钢板,制造工艺粗糙,使挡风闸门与闸框的配合间隙过大,工作后还需人工填料密封,降低了风机效率。
B4-72-11 Centrifugal Ventilator used by Mine Shaft is manually operated in anti-wind and 40 minutes for completion of an anti-wind event, failing to meet the standard of anti-wind within 10 minutes stipulated in “Coal Mine Safety Regulations”. In response to this problem, we design the windshield gate and the wind opening and closing device, the use of two years, the effect is good, an anti-wind time of only 3 minutes 20 seconds, to ensure safe production. First, the original structure of the fan anti-wind problems 1. The use of two thick 6mm round steel fan switch for the wind gate, due to the thin steel sheet, easy to deform after the wind pressure, resulting in the inconvenience of lifting the gate, the impact of anti The wind goes well. 2. With round steel, rough manufacturing process, so that the wind gate and gate frame with the gap is too large, the need for manual packing seal after work, reducing the fan efficiency.