WPG-100型光栅摄谱仪是国产仪器中性能较好的,目前使用单位较多。但此仪器控制箱的功能不能满足地质分析工作的需要。并且可靠性较差,自动化程度不高。按仪器原设计: 1.每次摄谱必须预燃。若把预燃时间继电器指针置“零”,则整机失控无法工作。这对于半定量全分析很不适合。 2.自动板移控制部分不耐用,不可靠。我们所用的这台仪器仅摄谱5000余样品,板移自动控制就失灵了。
WPG-100 grating spectrometer is a good performance of domestic instruments, the current use of more units. However, the function of this instrument control box can not meet the needs of geological analysis. And the reliability is poor, the degree of automation is not high. According to the original design of the instrument: 1. Each photo must be pre-burning. If the pre-burn time relay pointer set to “zero”, the whole machine out of control can not work. This is not suitable for semi-quantitative total analysis. 2. Automatic plate shift control part of the non-durable, not reliable. We use this instrument only up to 5,000 samples of samples, automatic plate shift control to failure.