论文部分内容阅读
本文介绍了适用于高 γ 释热率测定的量热计设计及在高通量工程试验反应堆(HFETR)的G_7,辐照孔道中的 γ 释热率测量,其测量误差在±4.5%以内.
In this paper, the design of a calorimeter for the measurement of high γ-rate of heat release and the measurement of the γ-rate of heat release in the G_7, irradiated cell of a high-throughput engineering test reactor (HFETR) are introduced. The measurement error is within ± 4.5%.