论文部分内容阅读
IIT研究院开发了一种技术,这种技术大大的增加了磁带和磁头的使用寿命,其方法就是在磁带的表面涂一层很美的非活性润润剂。试验是用各式各样的商品化的磁带和各式各样的磁头进行的,在环形试验机上,3M-900# ,通过五百之六以上,磁带仍無明显的影响,而反润滑的磁带作同样的试验只有三万次,使用润滑的磁带,磁头的磨损可以减小十倍、本文讲述这个技术,并给出IIT研究院得到的典型的试验结果。
The IIT Institute has developed a technology that dramatically increases the life of tapes and heads by applying a very thin layer of non-reactive lubricant to the surface of the tape. The test was performed on a wide variety of commercially available tapes and magnetic heads. On a ring tester, 3M-900 #, passing over five hundredths, the tape still had no noticeable effect, whereas the anti-lubricated The tape was tested for only 30,000 identical runs. Using a lubricated tape, the head wear can be reduced by a factor of ten. This article describes the technique and gives typical test results from the IIT Institute.