A more than 2-year follow-up of incomplete apposition after drug-eluting stent implantation

来源 :中华医学杂志(英文版) | 被引量 : 0次 | 上传用户:sanyueyusi
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background Incomplete stent apposition (ISA) has been demonstrated to be more common after drug-eluting stent (DES)implantation than after bare metal stent(BMS)implantation.Clinical outcomes of ISA remain controversial and the predictive accuracy of previous studies was limited by the short follow-up period of only 12-18 months.In the present study,we present the outcomes of a more than 2-year follow-up in patients with ISA after DES implantation.Methods From the clinical and core intravascular ultrasound(IVUS)database of the hospital,we jdentified 76 patients who had undergone DES implantation In de novo lesions between January 2004 and June 2005 and had received IVUS examination at a scheduled 6-month follow-up.Atotal of 13(17.1%)patients had documented ISA at the follow-up by IVUS.Clinical follow-up was available up to 41 months after DES implantation and up to 33 months after identification of ISA.Results Over a mean follow-up of(34±5)months(range 24-41 months),3 of the 13 patients(23.1%)suffered from ST elevated myocardial Infarction with one death.Angiography confirmed the very late stent thrombosis (ST) in the area with ISA.All the 3 patients were implanted with sirolimus eluting stents in left anterior descending artery(LAD)and the very late ST occurred at 29,31 and 32 months after DES implantation,and separately at 20,23 and 23 months after the identification of ISA.All of the 3 patients had antiplatelet therapy continued before suffering from ST, and had been apparently stable on antiplatelet monotherapy with aspirin for a long period following dual antiplatelet therapy with aspirin and clopidogrel for more than 12 months.Conclusion ISA of DES may be associated with a high incidence of very late stent thrombosis,even in clinically stable patients with dual antiplatelet therapy of at least 12 months after the procedure.
其他文献
Stevens-Johnson syndrome (SJS) is a serious and potentially life-threatening disease. Vanishing bile duct syndrome (VBDS) is a rare cause of progressive cholest
Background Tdggedng receptors expressed on myeloid cells(TREM)proteins are a family of cell surface receptors expressed broadly by cells of the myeloid lineage.
Hypnosis is a therapeutic technique that primarily involves attentive receptive concentration. Even though a small number of health professionals are trained in
Background Intratracheal instillation of blood induces self-repaired acute lung injury.However,the mechanism of repair has been unclear.Heme-oxygenase (HO)-1,wh
AIM: To investigate oxidative stress and lipid peroxi-dation in hepatic steatosis and the underlying implica-tions in pathological mechanisms of non-alcoholic f
Background The down-regulation of constitutive nitric oxide synthase (cNOS) and up-regulation of inducible nitric oxide synthase (iNOS) are associated with the
采集农田中表层、里层、深层土壤,采用正己烷:丙酮=1:1(V/V)作为提取剂[1,2],土壤样品于Florisil柱中净化,浓缩定容后,用电子捕获检测器检测,石英毛细管柱气相色谱法测定,用
Background Failure of balloon catheter passing through the occluded segment accounts for 10%-15% of all procedures during percutaneous coronary intervention(PCI
结合北京地区的特点,分析了产生大气可吸入颗粒物的原因,通过季节变化和实时跟踪调查,分析出产生可吸入颗粒物最主要的持续性的来源.
有机磷农药具有高效、低毒等特点被广泛应用于农业生产,其残留对生物和人类的健康构成了潜在的威胁.由于有机磷农药主要通过影响胆碱能系统的活性发挥其神经毒性作用,因此本