本文探讨了空调用冷却塔室外气象条件的确定原则,在对近4万组实测气象数据进行分析研究的基础上,得出了宜按最炎热时期频率为10%的干湿球温度作为空调用冷却塔室外气象条件的结论。进而统计整理出了全国10个地区室外计算干湿球温度,这对于冷却塔的设计制造以及选择计算都具有一定的参考价值。
Based on the analysis of nearly 40,000 sets of measured meteorological data, the paper concludes that the wet and dry bulb temperature of 10% at the hottest time should be used as the air conditioner Cooling tower outdoor weather conditions conclusion. And then statistics out the 10 regions of the country outside the calculation of wet and dry bulb temperature, which for the design and manufacture of cooling towers and select the calculation has a certain reference value.