Implementation and evaluation of slow-time Golay decoding for pre-clinical high-frequency color Dopp

来源 :2015两岸超声技术与医学研讨会 | 被引量 : 0次 | 上传用户:trulyliu
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background, Motivation and Objective Golay Complementary Sequence (GCS) can compensate the high attenuation of high-frequency ultrasound by elevating signal level with low range side lobe and low implementation cost. However, due to potential motion artifact, it is conventionally regarded as not applicable to blood flow detection. In our previous study, it has been demonstrated that the Doppler spectrum of GCS has the main-lobe signal apart from the side-lobe signal by half of the pulse-repetition-frequency (PRF). Therefore, GCS decoding can be performed by low-pass filtering in slow-time domain with cutoff frequency of PRF/4 to eliminate any motion artifact from side-lobe in Doppler imaging.
其他文献
High-fat diet(HFD) treatment as little as 3 d induced fatty liver,insulin resistance and adipose inflammation.n3 PUFAs and their metabolites eicosanoids mediate protective effects on several metabolic
会议
The current study aims to explore the signaling pathway involved in hyperhomocysteinemia(HHcy)-induced hepatic steatosis.First,we performed a meta-analysis involving 2 057 subjects and revealed that p
会议
目的:研究载脂蛋白A-Ⅰ模拟肽Reverse-D-4F(Rev-D4F)对高脂饮食C57BL/6J 小鼠内皮祖细胞(EPCs)动员和EPCs 功能的影响.方法:6 周龄C57 小鼠分为正常饮食、正常饮食并注射Rev-D4F、高脂饮食和高脂饮食并注射Rev-D4F 四组.流式细胞术等检测外周血细胞亚群和细胞因子的数量;免疫荧光法测定Sca-1、c-Kit 等的表达;MTT 等方法检测EPCs 的增殖
会议
Background, Motivation and Objective Magnetomotive ultrasound (MMUS) imaging is a method that enables the use of superparamagnetic iron oxide nanoparticles (SPIO NP) as an ultrasound contrast agent. I
会议
Background, Motivation and Objective Traditional ultrasound imagers suffer from a large data rate between their analog to digital converter (ADC) front-end and digital beamforming backend. This high a
会议
Background, Motivation and Objective In quantitative echocardiography, a robust and accurate automatic segmentation of the left ventricle (LV) is important. Poor image quality and the rapid motion of
会议
Background, Motivation and Objective Coded excitation can improve the signal-to-noise ratio (SNR) in medical ultrasound imaging.
会议
Background, Motivation and Objective Flow Mediated Dilation (FMD) is widely used to assess the endothelial function by ultrasound. Ideally, both the brachial artery wall shear stress (stimulus) and di
会议
Background, Motivation and Objective During neurosurgery, intraoperative imaging can serve to provide feedback on cerebrovascular hemodynamics and help monitor procedures such as the placement of flow
会议
Background, Motivation and Objective The peak blood velocity is a parameter of high medical interest used, for example, in the determination of carotid stenosis grade. The standard approach, which typ
会议