Comparison of Two Dose-response Relationship of Noise Exposure Evaluation Results with High Frequenc

来源 :第13届中国介入心脏病学大会(CJT2015) | 被引量 : 0次 | 上传用户:luote51499
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Background: Complex noise and its relation to hearing loss are difficult to measure and evaluate.In complex noise measurement,individual exposure results may not accurately represent lifetime noise exposure.Thus, the mean LAeq.8h values of individuals in the same workgroup were also used to represent LAeq.8h in our study.Our study aimed to explore whether the mean exposure levels of workers in the same workgroup represented real noise exposure better than individual exposure levels did.Methods: A cross-sectional study was conducted to establish a model for cumulative noise exposure (CNE) and hearing loss in 205 occupational noise-exposed workers who were recruited from two large automobile manufacturers in China.We used a personal noise dosimeter and a questionnaire to determine the workers' occupational noise exposure levels and exposure times, respectively.A qualified audiologist used standardized audiometric procedures to assess hearing acuity after at least 16 h of noise avoidance.Results: We observed that 88.3% of workers were exposed to more than 85 dB(A) of occupational noise (mean: 89.3 ± 4.2 dB(A)).The personal CNE (CNEp) and workgroup CNE (CNEg) were 100.5 ± 4.7 dB(A) and 100.5 ± 2.9 dB(A), respectively In the binary logistic regression analysis, we established a regression model with high-frequency hearing loss as the dependent variable and CNE as the independent variable.The Wald value was 5.014 with CNEp as the independent variable and 8.653 with CNEg as the independent variable.Furthermore, we found that the figure for CNEg was more similar to the stationary noise reference than CNEp was.The CNEg model was better than the CNEp model.In this circumstance, we can measure some subjects instead of the whole workgroup and save manpower.Conclusions: In a complex noise environment, the measurements of average noise exposure level of the workgroup can improve the accuracy and save manpower.
其他文献
  Background: Retroperitoneal fibrosis (RPF) is an uncommon disease that is characterized by development of fibrosclerotic tissues involving retroperitoneal s
会议
  Background: We investigated whether and to what extent the ratio between circulating fibrinogen (Fg) and its degradation products (FDP)reflects the severity
会议
  Background: Lack of fluoroscopic landmarks can make valve deployment more difficult in patients with absent aortic valve (AV) calcification.The goal of this
会议