Analysis of Dose Rate Response Characteristic of Three Kinds of Finger Shape Ionization Chamber for

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:wdj702
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Objective:To analyze three different kinds of finger shape ionization chamber of medical linear accelerator is used the response of the dose rate.Methods:Choose three different kinds of finger shape ionization chamber,they are respectively 0.6 cm3 PTW ionization chamber and 0.125 cm3 ionization chamber,IBA 0.01 cm3 of ionization chamber,accelerator in 100-600 cGy/min,within the limits of dose rate under the same measurement conditions and MU,respectively measuring and analysis of three different kinds of ionization chamber under the different working voltage and energy of the dose rate response characteristics.Results:Dosimeter working voltage and X ray energy are constantly,three kinds of ionization chamber of collection efficiency with the increase of the dose rate have a certain degree of lower,for the 6 mv X-ray energy,three kinds of ionization chamber corresponding to the maximum dose meter readings was reduced by 1.90%,2.51%and 1.90%,respectively,for 15 mv X-ray energy,the three largest ionization chamber was reduced by 3.60%,3.57%and 3.60%respectively; When dose rate must be collection efficiency with the increase of the working voltage and a certain degree of rise,when the working voltage higher collection efficiency is relatively stable.Conclusion:Different finger type of ionization chamber,the working voltage of dosimeter and dose rate change will have a certain influence on collection efficiency,In the clinical application of dose measurement on the linear accelerator,Need to test and analysis dose rate corresponding and the measuring equipment to ensure the accuracy of routine calibration and dose verification.
其他文献
Purpose:To develop and evaluate an effective real-time tracking and gating radiotherapy based on dMLC for mobile tumor.Methods:A novel technology has been proposed for mobile tumor radiotherapy,where
Purpose:To develop a pencil beam algorithm(PBA)for dose calculation of proton beams in both homogeneous and heterogeneous media.Methods:The proton PBA consisted of the integral depth-dose and the off-
Purpose:In IMRT QA,plan quality evaluation is made based on pass rate under preset acceptance criteria,mostly using gamma-values.This method is convenient but,its result highly depends on what the acc
会议
Purpose In IMRT QA,the geometric errors(GE),which differences between the reference and measured dose distribution caused by a rotation and shift of a dose distribution because of QA environment setti
会议
TOPAS is a newly developed Monte Carlo simulation tool that combines extensive radiation physics libraries available in Geant4 code and easy-to-use geometry and visualization features.Although TOPAS h
The single source channel of Leksell Gamma Knife was simulated using Monte Carlo N-Particle Transport Code System(MCNPX version).The accurate dose distribution in a water-equivalent sphere phantom of
Medical Physics research contributions have been dominated by development of conformal treatment delivery technologies along with planning,imaging,and dose prediction tools that support accurate deliv
会议
Purpose The 3-D reconstruction of the fluorescence yield is achieved by using a method that main interest is its ability to reconstruct the fluorescence distribution in media presenting heterogeneous
会议
Purpose:To systematically evaluate accumulative imaging doses to organs-at-risk and associated lifetime attributable risk(LAR)of cancer incidence caused by various radiological imaging procedures perf
Introduction:We have developing a collision-detection simulator between treatment units and a patient for dynamic wave arc(DWA)irradiation achieving dose delivery to a target by continuous ring and ga