论文部分内容阅读
Self-pressurization in a cylindrical ribbed tank which is partially filled with LH2 is investigated numerically under different rib spacing-to-height ratios.A Volume of Fluid (VOF) method is employed as well as a phase change model.Appropriate codes are incorporated into the Ansys Fluent by the user-defined functions to carry out the computations.