The Development and Application of Halogen Containing Carbohydrate Based Chiral Stationary Phases

来源 :第2届大连国际色谱学术报告会、第37届国际高效液相色谱及相关技术会议、第18届全国色谱学术报告会 | 被引量 : 0次 | 上传用户:s5871212
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  The chromatographic separation of chiral compounds is an important tool in the search for new pharmaceutical entities.Both HPLC and SFC separations of chiral chemicals are important tools for analytical determination and preparative isolation of enantiomeric mixtures.Existing chiral stationary phases can separate a wide variety of chiral mixtures.However there are still enantiomeric mixtures that are difficult to separate limiting their characterization.It is the focus of this study to characterize and understand the separation capabilities for new halogen containing carbohydrate based chiral stationary phases that we have developed.In addition to reporting the separation capabilities of the new phases we will also report on the loading capacity and overall robustness for these new phases.
其他文献
Packed bed stationary phase design has reached a point where transcolumn bed heterogeneities become a limiting factor to separation efficiency.Still, slurry packing a column is considered an art rathe
The most important innovation in the field of ordered mesoporous silicas (OMSs) is undoubtedly the use of bridged silsesquioxane molecules as precursors for the synthesis of periodic mesoporous organo
Laboratory samples of commercially available first-generation Chromolith columns are compared to their successor, the second-generation Chromolith columns.Plate height curve analysis allowed to determ
Poly(N-isopropylacylamide) (PNIPAAm), a typical temperature-responsive polymer, exhibits a reversible hydrophilic-hydrophobic change in water at its lower critical solution temperature (LCST) of 32℃,
Hydrophilic interaction liquid chromatography (HILIC) is an alternative method to reversed-phase liquid chromatography (RP-LC) for the separation of polar compounds.Hydrophilic stationary phase as the
Modern (U)HPLC columns with plate heights as low as 3-4 μm generate plate numbers on the order of 25 000-30 000 plates / 10 cm.For a 2.1x50 mm columns the peak variance is ca.5 μl2 (k =2).The separati
In this study, a novel reversed stationary phase based on dithiourea derivative modified silica (DT-Sil) was prepared and characterized, by infrared spectra and elemental analysis.Compared with the tr
Polysaccharide-based CPMs for high-performance liquid chromatography (HPLC), especially those based on phenylcarbamate and benzoate derivatives of cellulose and amylose, are well-known to exhibit a hi
Poly(N-Isopropylacrylamide) is a typical temperature responsive polymer which exhibits a reversible hydrophilic-hydrophobic change in water at its lower critical solution temperature (LCST) of 32℃.It
Three ionic liquid-modified porous polymers were synthesized with different imidazolium-based functional groups to solid-phase extraction of lactic acid from fermentation broth.The adsorption isotherm