Clinical feasibility of leakage and transmission radiation dosimetry using MLC of ELEKTA Synergy-S A

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:yuhuipin1
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Purpose:The leakage and transmission rate(LTR)of the new-type multileaf collimator(MLC)in the Elekta Synergy-S accelerator was measured,the effects of the X-ray energy and gantry angles on the LTR,as well as the application research of LTR in clinic,were discussed.Moreover,the causes of the leakage and transmission dose(LTD)were analyzed.Methods:With a PTW UNIDOS dosimeter and a MP3 3D water tank,under the condition of different Xray energies,the interleaf transmission,between-leaf leakage and leaf ends leakage at the reference position,as well as the LTR with changing the gantry angle,were measured.Moreover,the LTR change curves in the direction of gun-target(GT)and left-to-right(AB)in the isocentric plane were obtained,and the LTR was also measured at 0mm,50mm and 100mm off-axis,respectively.In clinical research,each patient was treated with the whole brain radiotherapy for both Plan 1 and Plan 2,Plan 1 was without jaws,but Plan 2 adopted jaws for shielding leakage and transmission irradiation therein,whose effects on the target volume and organs at risk(OARs,including eyes and lens)were studied.Results:At the reference position,the X-ray energy slightly affected the interleaf transmission,betweenleaf and leaf ends leakages.Moreover,the gravity had slight effect on the between-leaf leakage; the X-ray energy had little effect on the LTD change curves in the GT and AB directions.Based on the same X-ray energy,the LTD was rather low at the point off-axis,which showed a decreased tendency following with the point further away from the axis gradually.Furthermore,different X-ray energies also had a certain effect on the LTD at the same position away from the axis,and the LTRs were larger with 10MV and 18MV of X-ray than that with 6MV.Compared with Plan 1,the dose distribution of the target volume was superior,the maximum doses of eyes and lens were lower for Plan 2.Conclusion:The existence of interleaf leakage radiation remarkably affected the target volume and OARs,the collimator should be rotated using the jaws in accordance with the circumstances when optimizing the radiotherapy plans to protect OARs and normal tissues,which aimed to reduce the risks of irradiation.
其他文献
Purpose:In IMRT QA,plan quality evaluation is made based on pass rate under preset acceptance criteria,mostly using gamma-values.This method is convenient but,its result highly depends on what the acc
会议
Purpose In IMRT QA,the geometric errors(GE),which differences between the reference and measured dose distribution caused by a rotation and shift of a dose distribution because of QA environment setti
会议
TOPAS is a newly developed Monte Carlo simulation tool that combines extensive radiation physics libraries available in Geant4 code and easy-to-use geometry and visualization features.Although TOPAS h
The single source channel of Leksell Gamma Knife was simulated using Monte Carlo N-Particle Transport Code System(MCNPX version).The accurate dose distribution in a water-equivalent sphere phantom of
Medical Physics research contributions have been dominated by development of conformal treatment delivery technologies along with planning,imaging,and dose prediction tools that support accurate deliv
会议
Purpose The 3-D reconstruction of the fluorescence yield is achieved by using a method that main interest is its ability to reconstruct the fluorescence distribution in media presenting heterogeneous
会议
Purpose:To systematically evaluate accumulative imaging doses to organs-at-risk and associated lifetime attributable risk(LAR)of cancer incidence caused by various radiological imaging procedures perf
Introduction:We have developing a collision-detection simulator between treatment units and a patient for dynamic wave arc(DWA)irradiation achieving dose delivery to a target by continuous ring and ga
Objective:To analyze three different kinds of finger shape ionization chamber of medical linear accelerator is used the response of the dose rate.Methods:Choose three different kinds of finger shape i
Purpose:This study was to evaluate the setup accuracy of intensity modulated radiation therapy(IMRT)of ten patients with lung cancer by cone-beam computed tomography(CBCT)in Elekta Synergy S Linear Ac